10.n.DSP
NO
NO
Display weight at 10
times division number
under primary unit
*If (REGULA)= none this
parameter will not be available.
When yes is selected, some
menus will not be active.
YES
MOTiON
1-255
4
Motion window
1-255 = ±0.25d *(1-255)
*If (REGULA)=none, the max is 12
OVER.l.D
0-100
0
Overload display
limitation
0=FS+9d
1-100=101%FS -200%FS.
*If (REGULA)=none, the max is 10
ad.from
adc
adc
Where the A/D data
comes from
ADC
=local A/D chip on PCB
COM3
=COM3 interface
com3
ad.hspd
no
no
Speed of A/D conversion
NO
=10Hz;
YES
=80Hz;
if AD.FROM=COM3,this item will
not be shown
yes
UNITS
KG
yes
yes
UNITS key
YES = enable this unit
No = disable this unit
In trade applications, lb:oz is not
allowed
no
lb
yes
yes
no
oz
yes
no
no
lb:oz
yes
no
no
g
yes
yes
no
CONFG
SubMenu1
SubMenu2
Option
Default
Parameter Description