22
SB
I-240
Service Manual
3.
When
UNIT.KG
is displayed, use the
keys to select the piece
weight unit of measure.
4.
Press the
TARE/PRESET
key to confirm.
The previously entered piece weight will be shown (the default value is
000000).
5.
Use the
keys to input a new piece weight.
6.
Press and hold the
SETUP
key for 4 seconds to input the decimal point.
7.
Press the
TARE/PRESET
key to confirm and return to counting mode.
3.7.2 Enter the Piece Weight with a Sample of a Known Quantity
1.
Press the
UNIT/DATA
key.
2.
When
InP.PWt
is displayed, use
keys to select
SPL.PWT
.
3.
Press the
TARE/PRESET
key to access the "Get Piece Weight" mode.
4.
When
SPL.Lo
is displayed, remove any load from the platform and press the
TARE/PRESET
key to confirm.
If the scale hasn't stabilized,
SPL.Lo
will flash. After it has stabilized, it
will go to the next step.
5.
When
SPL.Hi
is displayed, place a sample of a known quantity onto the scale
platform and press the
TARE/PRESET
key.
If the scale hasn't stabilized,
SPL.Hi
will flash.
If the scale has stabilized,
INP.PCS
will be displayed quickly and the
previously entered piece weight will be displayed (the default value is
000000, and the position of decimal point is determined by CONFIG-
FUNC-PERCEN setting).
6.
Use the
keys to input the sample quantity.
NOTE: If the input piece weight is less than 0.5d (where d = the scale's readability,
see specifications), the indicator will display PWt.Er and will automatically return to
counting mode.
NOTE: At any time you can press ZERO/ON/OFF to exit "Get Piece Weight" and
return to counting mode.
Содержание SBI-240
Страница 1: ...SBI 240 Weighing Indicator Service Manual AWT35 501 Issue AA ...
Страница 5: ...SBI 240 Service Manual 5 ...
Страница 7: ......
Страница 9: ...ti E ...
Страница 10: ......
Страница 34: ...TARE PRESET SBI 240 Service Manual ...
Страница 57: ...SBI 240 Service Manual 55 Table 5 1 Location Code For Elevation and Latitude ...
Страница 76: ...74 SBI 240 Service Manual ...
Страница 77: ......