n.8001
Power-on start (no external input signal required)
Initial value
:
n. 01 01
(
H L
)
Control mode
:
all
Unit
:
~
Setting range
:
~
Modify effective time
:
“●”Can be modified at any time, take effect by re-powered on
Parameter function
:
H
:
00
:
Set the signal to always be invalid 01
:
Input positive signal from SI1 terminal
02
:
Input positive signal from SI2 terminal 03
:
Input positive signal from SI3 terminal
04
:
Input positive signal from SI4 terminal 05
:
Input positive signal from SI5 terminal
06
:
Input positive signal from SI6 terminal 07
:
Input positive signal from SI7 terminal
08
:
Input positive signal from SI8 terminal
80
:
Set the signal to always be active 81
:
Input reverse signal from SI1 terminal
82
:
Input reverse signal from SI2 83
:
Input reverse signal from SI3
84
:
Input reverse signal from SI4 85
:
Input reverse signal from SI5
86
:
Input reverse signal from SI6 87
:
Input reverse signal from SI7
L
:
00
:
External input is completely based on factory settings
,
the setting of
P5-10.H~P5-19.H
is
invalid
01
:
External input signal can be set freely
,
the setting of
P5-10.H~P5-19.H
is valid.
6.2.2 Motor rotation direction
◎
P0-05
Direction
selection
Note: After switching the direction, the signal
received by servo is reversed.
0X0005
Initial value
:
0
Control mode
:
1,2,3,4,5,6,7
Setting range
:
0,1
Modify effective time
:
“●”Can be modified at any time, take effect by re-powered on
Parameter function
:
0
:
Forward direction (from the load side is "counterclockwise rotation")
1
:
Forward direction (from the load side is "clockwise rotation" )
P0-05
Forward
Reverse
0
CCW
CW