![Brasiltec SC1-3003 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/brasiltec/sc1-3003/sc1-3003_technical-manual_2802340011.webp)
11
3.3.2 Input and output signal wiring
The input and output signals of the servo unit and its connection to the host device:
(1) Analog input circuit
Application mode: Speed control (analog voltage) P0-01: parameter setting 4
Torque Control (Analog Voltage) P0-01: Parameter setting 2
Circuit parameters: Input impedance RI = 13KΩ
Input voltage Vmax<=10V
(2) Pulse input circuit
M
40V
4
7
10
SO4-CO
M
Output
40V
11
35
AGND
Input
negative
of analog
3
6
AGND
Input negative
of analog
12
13
37
V-REF
Speed
analog
3
8
T-REF
Torque
analog
14
15
PULS-
Pulse
Input
39
-10V
Output
4
0
+10V
Output
16
17
PULS +5V
Pulse 5V
41
485 A
Bus
communic
ation
4
2
485 B
Bus line
Communicatio
n
18
19
PULS
+24V
Pulse24
V
43
4
4
20
21
DIR-
Direction
45
B+
Encoder
feedback
4
6
B-
Encoder
feedback
22
ZOC-
Z pulse
Negative
electrode
23
DIR +5V
Direction
5V
47
A+
Encoder
feedback
4
8
A-
Encoder
feedback
24
ZOC+
Z pulse
negative
electrode
25
DIR +24V
Direction
24V
49
Z+
Encoder
feedback
5
0
Z-
Encoder
feedback
Host device
Analog input circuit
Servo driver
+10V
-10V
T-REF Torque analog input
V-REF Speed analog input
AGND