Installation
MF2933/BIR3
5
Bradley Corporation • 215-1371 Rev. K; EN 06-915C
10-31-2005
7"
(178)
7-1/8" *
(181)
10"
(254)
10"
(254)
24" *
(610)
19-1/2"
(495)
28" *
(711)
7-1/2"
(191)
7"
(178)
9-1/2" *
(241)
SUPPLIES THROUGH FLOOR
(OPTIONAL) STUB UP 3"
1-1/2" NPT WASTE CONNECTION
THROUGH FLOOR - 3" FROM WALL
1/2 NPT SUPPLIES - 5" FROM WALL
STUB OUT MIN. 1-1/2"
FROM FLOOR
1/2 NPT SUPPLIES
STUB OUT MIN. 1-1/2"
FROM WALL
1-1/2 NPT WASTE CONNECTION
FOR USE WITH 1-1/2" TUBULAR P-TRAP
STUB OUT MIN. 1-1/2"
(2) APPROPRIATE ANCHORS
AND 3/8" BOLTS (SUPPLIED
BY INSTALLER TO MOUNT
BOWL TO WALL
MOUNTING PANELS
3"
(76)
5"
(127)
FINISHED FLOOR
7-1/2"
(191)
* Subtract 4" (101) from this dimension for juvenile height model.
1
Rough-ins
IMPORTANT:
Flush the supply lines before making connections. Debris in
supply lines will cause the valves to malfunction.
IMPORTANT:
Compliance and conformity to local codes and ordinances is
the responsibility of the installer.
IMPORTANT:
Wall anchors need to withstand 1000 lbs pull force.
ROUGH IN 1/2" NPT HOT AND
COLD SUPPLY LINES THROUGH
WALL OR FLOOR AT
DIMENSIONS SHOWN.
A
ROUGH IN 1-1/2" NPT DRAIN
WASTE CONNECTION THROUGH
WALL OR FLOOR AT
DIMENSIONS SHOWN.
B