Installation Instructions
8
2-28-2005
Installation Instructions continued . . .
Step 6: Assemble and install bowl
WARNING: Do not attempt to install the bowl by yourself. To prevent serious injury,
install the bowl with the assistance of another person and always use appropriate
lifting procedures.
1. Install two 3/8" wall anchors (supplied by installer) which will be used to mount the bowl to the
wall. (See Figure 1 on page 4).
2. Carefully remove the sprayhead cover (see Figure 9 on page 10)
3. With the help of an assistant, carefully lift the bowl onto the pedestal frame using appropriate
lifting procedures. Ensure bowl remains 3 - 4 inches from the wall.
WARNING: Do not leave the bowl on the pedestal unsupported, as it may fall and
cause personal injury or damage to property.
4. Install the two wall anchor brackets to the back of the bowl using the 3/8"- 16 x 1-1/2" hex-head
bolts, 13/32" I.D. plain washers, anchor plates, 3/8" I.D. lockwashers, and 3/8"- 16 hex nuts
provided as shown in Figure 5.
5. Uncoil the Touch Time switch leads and plastic tubing from the rear of the backsplash.
6. Slide the bowl back to the wall and secure the bowl’s wall brackets to the wall anchors with two
3/8" bolts and washers (supplied by installer)
7. Fasten the bowl to the upper bracket on the pedestal assembly with the two 1/4"- 20 x 1/2"
round-head screws and 5/16" I.D. washers supplied.
8. Install the drain spud in the bowl using plumber’s putty (see Figure 6).
NOTE: Discard rubber gasket included with drain spud. It cannot be used in this application.
9. From beneath bowl, thread the locknut with the spud washer onto the drain spud and tighten the
locknut against the bowl (see Figure 6).
10. Install strainer in the bowl drain using the two #10-24 x 1/2" flat socket head screws supplied.
11. Connect the drain trap (supplied by installer) to the drain spud and drain line.
Figure 5
Figure 6
Spud
Washer
#10-24 x 1/2"
Screw for
Strainer
Drain
Spud
Dome
Strainer
Discard this
washer; it is not
used on
washfountains.
Washfountain
Bowl
Spud
Locknut
Drain Assembly
Back View of Washfountain Bowl