Bradley Corporation • 215-1537 Rev. D; 06-915C
Terreon® Tri-Fount™ Washfountain with Touch Time® Control
Installation Instructions
MF2933/TT
7
2-28-2005
Installation Instructions continued . . .
Step 5: Install solenoid assembly
1. Connect the 1/2" NPT female end of the stop/check valves to the rough-ins.
2. Connect the supply hoses to the stop/check valves.
3. Inside the pedestal, install the two 1/4-20 x 1/2" screws (supplied with solenoid assembly) in the
mounting holes on the side of the left pedestal panel.
DO NOT
thread the screw completely
into the panel, but allow 5/16" of the screw to be exposed (see Figure 4)
4. Mount the valve bracket to the left side of the pedestal as shown.
IMPORTANT: The hose attached to the hot water inlet of the Vernatherm™ TMV
valve (marked with “H”) must be connected to the hot water rough-in.
5. Connect the supply hoses to the Vernatherm™ TMV valve assembly.
6. FOR OPTIONAL SINGLE TEMPERED SUPPLY: Attach the stop/check/valve to the 1/2" tempered
supply line. Connect the stop/check/valve to the solenoid valve with the flexible supply hose.
NOTE: The thermostatic mixing valve requires at least 115° F water from the hot water side for
proper operation. As with all lavatories, there will be a delay in obtaining warm water. If the hot
water is too far away from the washfountain, a circulating pump may be required.
Braided Hose
Cold Supply Inlet
Hot Supply
Inlet
Stop/Check Valve
Vernatherm™ TMV
Solenoid Valve Assembly
1/4-20 x 1/2" Screws
Figure 4