Installation
WF2613
Bradley
•
215-1451 Rev. F; ECN 13-00-001
3/5/2013 9
5b
Installing Supplies with Optional Soap Dispenser for
B/H drain units
A
Install hemmed end (not sharp end)
of support tube (welded seam toward
intersection of walls) with gasket onto bowl.
B
Connect 1/2" supply tubing to sprayhead.
• Using a sharp knife, cut tubing squarely
and remove any burrs. DO NOT pinch
or crush end of tubing.
• Loosen nut on fitting. Moisten end of
tube and push into fitting until it is firmly
seated. Tighten nut to secure tube
to fitting (make sure nut is securely
tightened).
• If connector leaks, reseat tubing
according to above procedure.
If leaking persists, replace male
connector, or call your Bradley
representative for assistance.
C
E
G
D
F
Place sprayhead with 1/2" tubing onto support
tube. Run tubing down through support tube.
Insert the 1-1/2" vent pipe through the infrared
module, sprayhead, and support tube.
Connect vent pipe to vent through
ceiling with pipe union.
Place infrared module assembly on top of
sprayhead. Drop two infrared module wires
down into the pedestal.
FOR UNITS WITH SOAP OPTION: Place the
spacer, soap dispenser and cover in position
on top of IR module. Slide tie bar over 1-1/2"
vent pipe 1/2" below top of soap dispenser lid
and secure with the two cap screws included
with the tie bar. Slide the dispenser cover over
1-1/2" vent pipe and secure with the two cap
screws included with the tie bar.
FOR UNITS WITHOUT SOAP OPTION: Slide
tie bar over 1-1/2" vent pipe, 1/2" below top of
infrared module and secure with set screws.
Slide the dispenser cover over 1-1/2" vent pipe
and secure with the two cap screws included
with the tie bar.
Dispenser
Cover
Cap Screw
(160-108)
Supplies 1/2"
Nominal Copper
Tubing
Type "H" Drain
(Supplies from Below)
Type "B" Drain
Soap
Dispenser
Spacer
(113-155A)
Soap Dispenser
Gasket (124-066)
IR Module
Assembly
(S83-046)
Sprayhead
(S05-054C)
Support Tube
(S57-005)
Support Tube
Gasket (125-011)
Valve
Assembly
Hot
Cold
Vented Trap
(111-024)
Upper Tie Bar Location
for Unit with Soap
(159-020)
Upper Tie Bar Location
for Unit without Soap
(159-020)
1-1/2" Vent Pipe
Soap
Dispenser Lid
Parts Shown
in Box are
for Unit
with Soap
Dispenser
For models with optional paper towel
dispensers, tie pipe assembly, or shroud,
see separate instruction sheets
Upper Tie Bar
(159-009A)
Corner Restraining
Bracket (S70-061E)
(Fits Around Support Tube)