TROUBLE SHOOTING

Checklist

Before calling for service, check the following
points to see if the cause of trouble can be
identified and corrected. Reviewing this checklist
may eliminate the need of a service call and
quickly restore hot water service.

Not enough or no hot water

1. Ensure that the electrical disconnect switch 

serving the water heater is in the “ON” 
position.  The pilot switch(es) on the cabinet 
should also be in the on position.  In some 
areas, water heater electrical service may be 
limited by the power company.  If the heater 
operates on a controlled circuit, heater 
recovery may be affected.

2. Check the fuses. The electrical disconnect 

switch usually contains fuses. The water 
heater has fuses located behind the cabinet 
front door.  When replacing internal fuses in 
the water heater control panel, insure that the 
same type and size of fuse is used.

3. If the water was excessively hot and is now 

cold, the manual reset high limit may
have operated.

To reset, turn off electricity and push the reset 
button.  The high limit is located above the 
upper most heating element in the storage tank. 
On some high input models additional hi 
limits may be located behind the side access 
panel. Repeat operation of the high 
temperature cut-off should be investigated by 
your mechanical contractor or by a qualified 
technician.  A contactor or thermostat may be 
malfunctioning.

4. The capacity of the heater may have been 

exceeded by a large demand for hot water. 
Large demands require a recovery period to 
restore water temperature.

5. Cold incoming water temperature will 

lengthen the time required to heat water  to the 
desired temperature. If the heater was 
installed in the summer when incoming water 
temperature was warm, colder ground water 
in the winter months can create the effect of 
less hot water.

6. Look for wasted hot water and leaking or 

open hot water faucets.

7. Sediment or lime scale may be affecting water 

heater operation.  Refer to “Maintenance”
for details.

Water is too hot

Refer to “Temperature Regulation” and reset the
thermostat setpoint to a lower temperature that
will meet requirements for hot water

Water heater makes sounds

1. Sediment or lime scale accumulation on the 

elements causes sizzling and hissing noises,
when the heater is operating.  If this occurs, 
the tank bottom and elements should be 
cleaned. Refer to “MAINTENANCE”
for details.

2. Some of the electrical components of the 

water make sounds which are normal. 
Contactors will “click” or snap as the heater 
starts and stops. Transformers and contactors 
often hum.

Water leakage is suspected

1. Check to see if the drain valve is

tightly closed.

2. The apparent leakage may be condensation 

which forms on cool surfaces of the heater 
and piping.

3. If the outlet of the relief valve if leaking, it 

may represent:

a.  Excessive water pressure.
b.  Excessive water temperature.
c.  Faulty relief valve.

Содержание CHP-I&S-01

Страница 1: ...acturer s warranty Follow start up procedure in the manual Water heater corrosion and component failure caused by air borne chemical vapors is not covered under the manufacturer s warranty Corrosion d...

Страница 2: ...on 8 Relief Valve 8 Thermal Expansion 8 Cathodic Protection 9 Electrical Service Electrical Connection 9 Wire Sizing 9 Fusing 9 Electrical Connection 9 Jacket Assembly 10 Standard and Optional Control...

Страница 3: ...3 FIG 2 Front View Vertical Square Models FIG 1 Front View Vertical Round Models FIG 3 Front View Horizontal Models...

Страница 4: ...t must conform to the CAE C22 1 Canadian Electrical Code Part 1 and or local Electrical Codes This complete appliance is design certified and Listed by Underwriters Laboratories as a commercial storag...

Страница 5: ...ture of the space where the appliance is installed must not go below 32 F 0 C or above 104 F 40 C The lower pan of the horizontal water heater jacket or vertical square water heater jacket is speciall...

Страница 6: ...d heating elements Top 12 30cm for service access to electrical service water connections and piping Water Pipes 1 25 4mm 6 FIG 5 Clearances from Combustible Construction 12 36 6 FIG 4 Clearances from...

Страница 7: ...oor following applicable architectural and local code requirements or accepted standards for the specific site and model purchased In areas prone to seismic activity it is recommended that the water h...

Страница 8: ...ater heater is supplied with a temperature and pressure relief valve s sized in accordance with ASME Boiler and Pressure Vessel Code Section IV Some water heaters may be supplied with an optional pres...

Страница 9: ...NFPA No 70 When the appliance is installed in Canada it must conform to the CAE C22 1 Canadian Electrical Code Part 1 and or local Electrical Codes 1 Use copper conductors only All wiring between the...

Страница 10: ...sity immersion heating elements with an incoloy sheath Internal fusing of all elements in a maximum of 48 amp increments provides additional safety Fuse cartridges are related at 1 000 000 amps interr...

Страница 11: ...of various control failures Time clock to control off on cycles of the heater as programmed by the owner or electric utility requirements Low water pressure switch High water pressure switch A main po...

Страница 12: ...l circuit supplying power to the immersion heating elements When the thermostat is satisfied the contactor coil is de energized and power to the heating elements is turned off CONTROL CIRCUIT TRANSFOR...

Страница 13: ...has an adjustable thermostat to control water temperature The thermostat is factory pre set at approximately 125 F 51 7 C or less Households with small children or invalids may require a 120 F 48 9 C...

Страница 14: ...scalds Children disabled and elderly are at highest risk of being scalded See instruction manual before setting temperature at heating appliance If this appliance is used to produce water that could...

Страница 15: ...arrow Down arrow and Enter Select Key Sequentially prompts the user as to what parameter is being displayed set point differential stage energized operation mode heat indication of assigned stage 1 2...

Страница 16: ...rential 8o F Output Energized Stage One Energized at 152o F Output De energized Stage One De energized at 160o F Each available stage of operation must be programmed with a set point and a differentia...

Страница 17: ...r Down Arrow key to decrease to the desired set point 8 Press Enter to enter the displayed value into memory 9 Press Select to display the current stage switching differential 10 Press Up Arrow key to...

Страница 18: ...or cannot be field repaired Replace the water heater s electronic temperature control OE ROM Error The internal ROM of the microprocessor in the boiler s electronic temperature control is defective Th...

Страница 19: ...ment gasket must be replaced with a new gasket when an element is removed for inspection cleaning or replacement The optional safety door interlock is an electrically operated locking pawl that is ene...

Страница 20: ...eater storage tank If the water pressure drops below an adjustable set point the control circuit is opened and operation of the water heater is shut down The low water pressure switch may be specified...

Страница 21: ...schedule is maintained in periods where there may be power interruptions The time clock works by making and breaking the 120 VAC control circuit to the contactor coils to shut down operation of the h...

Страница 22: ...expansion The system must make allowance for this expansion If an expansion tank is not provided in the system water pressure may increase to the point where the water heater s temperature and pressu...

Страница 23: ...starts heating check the contactors for buzzing or chattering during operation If noise is detected turn off main power open the control panel and clean the contact points of the magnetic contactor s...

Страница 24: ...ng and start up procedure to place the water heater back into service Listed below are items that must be checked to insure safe reliable operations Verify proper operation after servicing The tempera...

Страница 25: ...in the hot water system because heated water increases the rate of corrosive chemical reactions 25 Water heater maintenance includes periodic tank flushing cleaning and removal of lime scale from the...

Страница 26: ...e exposed ends of the elements which are not accessible through the front element access door 3 Disconnect the wires attached to the element terminals Try not to disturb the wiring unnecessarily and r...

Страница 27: ...contactor or thermostat may be malfunctioning 4 The capacity of the heater may have been exceeded by a large demand for hot water Large demands require a recovery period to restore water temperature 5...

Страница 28: ...encountered local codes or inspection agency should be consulted to determine which of the following procedures is acceptable in your area Installation of an expansion tank Removal of the check valve...

Отзывы: