should be metallic pipe or a high temperature
plastic pipe (CPVC, etc.) to insure that hot water
flow will not damage the discharge piping from
the relief valve.

In hard water areas, water treatment should be
used to reduce the introduction of minerals to the
system.  Minerals in the water can collect in the
storage tank and on the immersion heating
elements causing noise on operation. Excessive
build up of minerals on the surface of the heating
elements can reduce the service life of the
elements and lead to a non-warrantable failure.

Proper operation of this electric water heater is
based on heating potable water with a hardness of
5 to 25 grains per gallon and a total dissolved
solids not exceeding 350 PPM. Consult the
manufacturer when heating potable water
exceeding these specifications. Heating of high
hardness and/or high total dissolved solids water
may require frequent cleaning of the storage tank
and heating elements to achieve proper operation.
The higher the level of dissolved solids or  water
hardness, the faster the dissolved minerals in the
water will precipitate out and form scale deposits
on the heating elements and in the storage tank.
The level of  scale  formation is also accelerated
as stored water temperature increases. Water with
a hardness of less than 5 grains per gallon will
usually have a low pH which can be aggressive
and corrosive causing non-warrantable damage to
the storage tank, heating elements and associated
piping. Corrosion due to water chemistry
generally shows up first in the hot water system
because heated water increases the rate of
corrosive chemical reactions.

25

Water heater maintenance includes periodic tank
flushing, cleaning and removal of lime scale from
the heating elements.  Where used, the water
heating system circulating pump should be oiled.

1. Turn off main power at the electrical 

disconnect switch.

2. Open the drain valve.  Allow water to flow 

until it runs clean.

3. Close the drain valve when finished flushing.

4. Turn on the electrical disconnect switch

(after filling).

Water born impurities consist of dissolved
minerals which precipitate out of the heated water
and fine particles of soil and sand which settle out
and form a layer of sediment on the bottom of the
tank. In time, if not removed, the level of
sediment might reach the heating elements.

For convenience, sediment removal and element
lime scale removal should be performed at the
same time as follows:

Sediment and Lime Scale Removal

Sediment and lime scale accumulation on the 
heating elements is a normal condition 
common to all immersion type elements.  Factors
which affect the amount of this formation are:

1. Amount of hot water  used.  As the volume 

of water increases, more scale results.

2. Water temperature.  As the temperature of the 

water is increased, more scale is deposited on 
the elements.

3. Characteristics of water supply.  Regardless 

of water treatment, the elements should be 
examined regularly.

Avoid contact with hot

discharge water. Insure that no one is in
front of or around the relief valve
discharge line.

Make sure that the

extremely hot water manually discharged
from the relief valve will not cause bodily
injury or property damage.

CAUTION:

WATER CHEMISTRY

FLUSHING THE STORAGE TANK

SEDIMENT REMOVAL

Содержание CHP-I&S-01

Страница 1: ...acturer s warranty Follow start up procedure in the manual Water heater corrosion and component failure caused by air borne chemical vapors is not covered under the manufacturer s warranty Corrosion d...

Страница 2: ...on 8 Relief Valve 8 Thermal Expansion 8 Cathodic Protection 9 Electrical Service Electrical Connection 9 Wire Sizing 9 Fusing 9 Electrical Connection 9 Jacket Assembly 10 Standard and Optional Control...

Страница 3: ...3 FIG 2 Front View Vertical Square Models FIG 1 Front View Vertical Round Models FIG 3 Front View Horizontal Models...

Страница 4: ...t must conform to the CAE C22 1 Canadian Electrical Code Part 1 and or local Electrical Codes This complete appliance is design certified and Listed by Underwriters Laboratories as a commercial storag...

Страница 5: ...ture of the space where the appliance is installed must not go below 32 F 0 C or above 104 F 40 C The lower pan of the horizontal water heater jacket or vertical square water heater jacket is speciall...

Страница 6: ...d heating elements Top 12 30cm for service access to electrical service water connections and piping Water Pipes 1 25 4mm 6 FIG 5 Clearances from Combustible Construction 12 36 6 FIG 4 Clearances from...

Страница 7: ...oor following applicable architectural and local code requirements or accepted standards for the specific site and model purchased In areas prone to seismic activity it is recommended that the water h...

Страница 8: ...ater heater is supplied with a temperature and pressure relief valve s sized in accordance with ASME Boiler and Pressure Vessel Code Section IV Some water heaters may be supplied with an optional pres...

Страница 9: ...NFPA No 70 When the appliance is installed in Canada it must conform to the CAE C22 1 Canadian Electrical Code Part 1 and or local Electrical Codes 1 Use copper conductors only All wiring between the...

Страница 10: ...sity immersion heating elements with an incoloy sheath Internal fusing of all elements in a maximum of 48 amp increments provides additional safety Fuse cartridges are related at 1 000 000 amps interr...

Страница 11: ...of various control failures Time clock to control off on cycles of the heater as programmed by the owner or electric utility requirements Low water pressure switch High water pressure switch A main po...

Страница 12: ...l circuit supplying power to the immersion heating elements When the thermostat is satisfied the contactor coil is de energized and power to the heating elements is turned off CONTROL CIRCUIT TRANSFOR...

Страница 13: ...has an adjustable thermostat to control water temperature The thermostat is factory pre set at approximately 125 F 51 7 C or less Households with small children or invalids may require a 120 F 48 9 C...

Страница 14: ...scalds Children disabled and elderly are at highest risk of being scalded See instruction manual before setting temperature at heating appliance If this appliance is used to produce water that could...

Страница 15: ...arrow Down arrow and Enter Select Key Sequentially prompts the user as to what parameter is being displayed set point differential stage energized operation mode heat indication of assigned stage 1 2...

Страница 16: ...rential 8o F Output Energized Stage One Energized at 152o F Output De energized Stage One De energized at 160o F Each available stage of operation must be programmed with a set point and a differentia...

Страница 17: ...r Down Arrow key to decrease to the desired set point 8 Press Enter to enter the displayed value into memory 9 Press Select to display the current stage switching differential 10 Press Up Arrow key to...

Страница 18: ...or cannot be field repaired Replace the water heater s electronic temperature control OE ROM Error The internal ROM of the microprocessor in the boiler s electronic temperature control is defective Th...

Страница 19: ...ment gasket must be replaced with a new gasket when an element is removed for inspection cleaning or replacement The optional safety door interlock is an electrically operated locking pawl that is ene...

Страница 20: ...eater storage tank If the water pressure drops below an adjustable set point the control circuit is opened and operation of the water heater is shut down The low water pressure switch may be specified...

Страница 21: ...schedule is maintained in periods where there may be power interruptions The time clock works by making and breaking the 120 VAC control circuit to the contactor coils to shut down operation of the h...

Страница 22: ...expansion The system must make allowance for this expansion If an expansion tank is not provided in the system water pressure may increase to the point where the water heater s temperature and pressu...

Страница 23: ...starts heating check the contactors for buzzing or chattering during operation If noise is detected turn off main power open the control panel and clean the contact points of the magnetic contactor s...

Страница 24: ...ng and start up procedure to place the water heater back into service Listed below are items that must be checked to insure safe reliable operations Verify proper operation after servicing The tempera...

Страница 25: ...in the hot water system because heated water increases the rate of corrosive chemical reactions 25 Water heater maintenance includes periodic tank flushing cleaning and removal of lime scale from the...

Страница 26: ...e exposed ends of the elements which are not accessible through the front element access door 3 Disconnect the wires attached to the element terminals Try not to disturb the wiring unnecessarily and r...

Страница 27: ...contactor or thermostat may be malfunctioning 4 The capacity of the heater may have been exceeded by a large demand for hot water Large demands require a recovery period to restore water temperature 5...

Страница 28: ...encountered local codes or inspection agency should be consulted to determine which of the following procedures is acceptable in your area Installation of an expansion tank Removal of the check valve...

Отзывы: