20
Trouble shooting
Sprühboy 14 Airmix Edition 05.07
6. Trouble
shooting
Fault Cause
Remedy
Agent pressure is constantly
dropping
Leaks
- Check all visible connections.
The agent to be processed has not
been properly mixed, e.g. clotting
- Check the agent to be
processed.
The agent is not liquid
- Check the agent to be
processed.
Agent contaminated
- Check the agent to be
processed.
Agent-nozzle clogged
- Check the agent nozzle, refer to
page in this regard 19.
The agent nozzle does not spray
evenly
Non-return valve in the agent
vessel connection piece defective
- Replace the non-return valve.
Nozzle needle does not shut
- Check the nozzle needle.
Nozzle needle seal set defective
- Replace the nozzle needle seal
set.
Agent-nozzle clogged
- Clean the agent nozzle using
hot water.
Nozzle needle guide defective
- Contact the maintenance
service.
Spray gun does not shut
Seal for air piston defective
- Contact the maintenance
service.
The agent nozzle does not spray
evenly
The agent to be processed has not
been properly mixed, e.g. clotting
- Check the agent to be
processed.
The stainless steel pressure vessel
is empty
- Top up with agent.
The spray gun only sprays air
The agent is not liquid
- Check the agent to be
processed.