Putting into operation
15
Sprühboy 14 Airmix Edition 05.07
4.3.1
Adjust spray gun for rotary, flat or
wide spraying
Rotary, flat or wide spraying is adjusted by means of
different engagement depths of the adjusting screw
(1). The adjustment is continuously variable.
Rotary spraying:
- Unscrew the adjusting screw (1) up to the stop.
Flat spraying:
- Completely screw the adjusting screw in (1) up to
the stop .
4.3.2
Adjusting the agent quantity
- Unscrew the locknut (1) at the agent quantity
adjusting screw (2).
- Pull the spray gun trigger (3).
- At the same time, turn the agent quantity adjusting
screw (2), until you consider the sprayed agent
quantity to be sufficient.
- Secure this position of the agent quantity
adjusting screw (2), by firmly retightening the
locknut (1).
The engagement depth of the agent
quantity adjusting screw (2) determines
the amount of agent sprayed by the
spray gun. Turn the agent quantity
adjusting screw into the desired
direction.
Increasing the agent quantity - turn
the agent quantity adjusting screw (2)
clockwise (+).
Reducing the agent quantity – turn
the agent quantity adjusting screw (2)
anti-clockwise (-).
1
1 2
3