background image

 

Iss A 05/14 

10 

8

 

Spare Parts List 

                           

 

 

Type 

Inlet End Cover

 

A

 

Outlet End Cover

 

B

 

Pressure Relief Valve

 

C

 

Mounting Foot

 

D

 

End Cover Gasket

 

E

 

2-3737 

EX002-3757CI 

EX032-4057CI 

4028 

4476 

3787 

3-3738 

EX003-3758CI 

EX033-4058CI 

4028 

4477 

3788 

4-3739 

EX004-3759CI 

EX034-4059CI 

4028 

4478 

3789 

5-3740 

EX005-3760CI 

EX035-4060CI 

3795 

4479 

3790 

6-3741 

EX006-3761CI 

EX036-4061CI 

3795 

4480 

3791 

8-3742 

EX008-3762CI 

EX038-4062CI 

3795 

4481 

3792 

10-3743 

EX010-3763CI 

EX040-4063CI 

3795 

4482 

3793 

12-3744 

EX012-3902CI 

EX042-4064CI 

3795 

4483 

3862 

15-5745 

EX043-5757CI 

EX044-5758CI 

3795 

4484 

5759 

 

  

 

 

Type 

Inlet End Cover

 

A

 

Outlet End Cover

 

B

 

Pressure Relief Valve

 

C

 

Mounting Foot

 

D

 

End Cover Gasket

 

E

 

2-5837 

EX062-5334CI 

EX062-5334CI 

4028 

4476 

3787 

3-5838 

EX063-5335CI 

EX063-5335CI 

4028 

4477 

3788 

4-5839 

EX064-5336CI 

EX064-5336CI 

4028 

4478 

3789 

5-5840 

EX065-5337CI 

EX065-5337CI 

3795 

4479 

3790 

6-5841 

EX066-4982CI 

EX066-4982CI 

3795 

4480 

3791 

8-5842 

EX067-4984CI 

EX067-4984CI 

3795 

4481 

3792 

10-5843 

EX068-4987CI 

EX068-4987CI 

3795 

4482 

3793 

12-5844 

EX069-5338CI 

EX069-5338CI 

3795 

4483 

3862 

15-5845 

EX070-5339CI 

EX070-5339CI 

3795 

4484 

5759 

Exhaust Gas Heat Exchangers 
with Straight End Covers 

Exhaust Gas Heat Exchangers 
with Right Angle End Covers 

Содержание 10-32-3744-5

Страница 1: ...EXHAUST GAS HEAT EXCHANGERS Installation Operation Maintenance Guide REG NO FM 38224 BS EN ISO 9001 2008 ...

Страница 2: ...eep the Installation Operation Maintenance Guide for all future reference to ensure the long lasting performance from your Exhaust Gas Heat Exchanger All rights reserved E J Bowman Birmingham Ltd reserve the right to change specification and technical alteration without prior notice No part of this guide may be reproduced or transmitted in any form or by any means including reproduction or recordi...

Страница 3: ... T A L L A T I O N 2 1 Transport storage 6 2 2 Installation 6 2 3 Connecting the heat exchanger 7 3 O P E R A T I O N 7 4 C O M M I S S I O N I N G 7 5 M A I N T E N A N C E R E P A I R 5 1 General Maintenance 8 5 2 Exhaust Gas Heat Exchanger Cleaning 8 6 W A R R A N T Y 8 7 P E R F O R M A N C E 9 8 S P A R E P A R T S L I S T 1 0 E J Bowman Birmingham Ltd Chester Street Birmingham B6 4AP United ...

Страница 4: ...only be used for its intended use In the event of breakdowns which may compromise safety a qualified technician must always be contacted 1 2 Safety Instructions The following symbols are used in these operating instructions This symbol indicates an immediate danger to health Failure to comply with this instruction may result in severe injury This symbol indicates a possible danger to health Failur...

Страница 5: ...rking 1 4 Potential Hazards The heat exchanger may be damaged or leak if the maximum permissible operating pressure is exceeded Connections on the exhaust gas side of the heat exchanger may reach temperatures as high as 700 C Connections on the cooling water side of the heat exchanger may reach temperatures as high as 110 C 1 5 Safety Measures at Installation Site The heat exchanger should not be ...

Страница 6: ...dary circuit is fully vented via the vent plug fitted in order to prevent any aeration taking place which can cause erosion of the tubes c If ethylene glycol or any other heat transfer fluid is used in the secondary circuit adequate mixing should be performed prior to filling of the heat exchanger d If temperature control sensors are fitted to either the primary or secondary circuits of the heat e...

Страница 7: ...ircuit pumps are in continual operation whenever the primary circuit is in operation c Provision should also be made to ensure that any valves or ancillary equipment associated with either the primary or secondary side of the heat exchanger cannot be accidentally turned off thereby preventing flow through the heat exchanger d It is very important that the secondary circuit is fully vented via the ...

Страница 8: ...vailable from companies such as Easy Products www easyproductsltd com d Detergents or chemicals suitable for use with stainless steels can be used if fouling is severe Allow time for the detergent or chemical cleaner to work before hosing down with plenty of water e The tube stack should be flushed through with clean water to remove all traces of cleaning chemicals detergents If necessary the clea...

Страница 9: ...very kW Exhaust Gas Pressure Drop kPa 2 25 3737 4 16 1 2 210 9 5 1 6 2 32 3737 5 16 1 2 170 11 5 1 8 3 32 3738 5 32 2 4 210 19 1 5 3 40 3738 6 32 2 4 170 21 1 7 3 60 3738 8 32 2 4 120 23 2 2 4 32 3739 5 60 4 5 210 35 1 3 4 40 3739 6 60 4 5 170 39 1 4 4 60 3739 8 60 4 5 120 43 1 8 5 32 3740 5 90 6 7 210 53 1 2 5 40 3739 6 60 4 5 170 39 1 4 5 60 3740 8 90 6 7 120 65 1 8 6 32 3741 5 140 10 5 210 82 1...

Страница 10: ...3862 15 5745 EX043 5757CI EX044 5758CI 3795 4484 5759 Type Inlet End Cover A Outlet End Cover B Pressure Relief Valve C Mounting Foot D End Cover Gasket E 2 5837 EX062 5334CI EX062 5334CI 4028 4476 3787 3 5838 EX063 5335CI EX063 5335CI 4028 4477 3788 4 5839 EX064 5336CI EX064 5336CI 4028 4478 3789 5 5840 EX065 5337CI EX065 5337CI 3795 4479 3790 6 5841 EX066 4982CI EX066 4982CI 3795 4480 3791 8 584...

Страница 11: ...ineTestHouseCooling MiningIndustry MarineCooling SwimmingPool SpaIndustry FishingIndustryCooling The product range includes MarineHeatExchangers HeaderTankHeatExchangers SwimmingPoolHeatExchangers ChargeAirCoolers StainlessSteelHeatExchangers InlinePlateTypeHeatExchangers FuelCoolers Shell TubeHeatExchangers TitaniumHeatExchangers Aftercoolers AquaticHeatExchangers Non StorageCalorifiers ...

Отзывы: