Iss A 05/14
9
7 Performance
Typical examples of exhaust gas heat exchanger performance. The figures below are a general
guide only and are not based on any particular natural gas engine. They assume an air/fuel
ratio of 10.23 : 1 by volume, a fuel consumption of 0.34m
3
/kWh (measured at 1.013 bar and
15°C) and an exhaust gas temperature of 600°C and a water temperature of 80°C.
Figures are based on new and clean conditions.
E.J. Bowman (Birmingham) Ltd, reserve the right to change specification and technical alteration without prior notice.
Type
Typical
Engine Power
kW
Exhaust Gas Flow
kg/min
Exhaust Gas
Outlet Temp
°C
Heat Recovery
kW
Exhaust Gas
Pressure Drop
kPa
2-25-3737-4
16
1.2
210
9.5
1.6
2-32-3737-5
16
1.2
170
11.5
1.8
3-32-3738-5
32
2.4
210
19
1.5
3-40-3738-6
32
2.4
170
21
1.7
3-60-3738-8
32
2.4
120
23
2.2
4-32-3739-5
60
4.5
210
35
1.3
4-40-3739-6
60
4.5
170
39
1.4
4-60-3739-8
60
4.5
120
43
1.8
5-32-3740-5
90
6.7
210
53
1.2
5-40-3739-6
60
4.5
170
39
1.4
5-60-3740-8
90
6.7
120
65
1.8
6-32-3741-5
140
10.5
210
82
1.3
6-40-3741-6
140
10.5
170
90
1.4
6-60-3741-8
140
10.5
120
101
1.9
8-32-3742-5
250
18.7
210
147
1.3
8-40-3742-6
250
18.7
170
161
1.4
8-60-3742-8
250
18.7
120
181
1.8
10-32-3744-5
400
30
210
236
1.3
10-40-3743-6
400
30
170
256
1.4
10-60-3743-8
400
30
120
288
1.8
12-32-3744-5
600
45
210
353
1.3
12-40-3744-6
600
45
170
388
1.5
12-60-3744-8
600
45
120
425
1.9
15-40-5745-6
950
70
170
604
1.4
15-60-5745-8
950
70
120
670
1.9