4-2
370 Outrage
Section 4 • Electrical System
R
You must stop the engine(s) before moving
the battery switch(es) to the “OFF” position.
!
CAUTION
by the retaining brackets. The trays will ensure that
while underway the batteries will not move around,
thus causing damage to components fi tted in the
same area.
The batteries can be removed from the trays by
fi rst removing the negative wires from the terminal
posts followed by removing the positive wires then
removing the retaining lid on the battery tray.
Battery Charger
The battery charger, mounted on the port side of
the battery trays (See fi gure 4.1.1) automatically
increases current output when there is a drop in
battery voltage. When the batteries are charged,
the unit maintains a small current fl ow to keep the
batteries fully charged and ready for service without
overcharging.
Overload Protection
If an electrical short or overload occurs in the
electrical system the charger will reduce its output
voltage to avoid internal damage. When an electrical
short occurs, the red LED on the front panel of
the unit will be illuminated. The overload or short
must be removed in order for the charger to resume
charging characteristics.
• Never use an open fl ame in the battery
storage area.
• Avoid striking sparks near the battery.
• A battery will explode if a fl ame or spark
ignites the free hydrogen given off during
charging.
• The battery should always be disconnected
before doing any work or maintenance on
the electrical system.
• If equipped with a battery switch, you will
need to stop the engine before moving the
switch to the “OFF” position.
!
CAUTION
Your boat uses battery switches (one for each engine)
to control delivery of DC power from the batteries.
These battery switches are advanced electric relay
switches located on the forward port bulkhead in the
bilge above the battery bank and are actuated via a
rocker switch on the DC distribution panel.
The DC distribution pane is located behind an access
door on the starboard gunnel opposite the control
station.
When the engines are shut down or not providing
a charge, the boats systems will draw power from
the center battery. This will allow you to run all the
boats functions without affecting the port or starboard
batteries.
Battery Switches
Maintenance
The charger is fully automatic and requires no
maintenance. However, the battery terminals should
be cleaned periodically with baking soda and
all connections tightened to provide trouble free
operation.
Each battery switch on the panel (See fi g. 4.11.1) is
wired to a remote switch located above the battery
bank in the bilge (See fi g. 4.1.1).
Remote Battery Switches
The three battery banks on the 370 Outrage are
automatically connected in parallel through the use of
ACRs (Automatic Charging Relay) when a suffi cient
charging source is present. The battery banks are
automatically separated when the charging source
falls below a certain voltage level for a predetermined
amount of time.
The use of ACRs eliminates the need for the operator
to monitor battery voltage and decide whether or
not it is ok to parallel the battery banks. It also
Automatic Charging Relays (ACR)
Содержание 370 Outrage
Страница 2: ......
Страница 20: ...xx 370 Outrage R THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 146: ...3 66 370 Outrage Section 3 Systems Components Overview Operation R THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 162: ...4 16 370 Outrage Section 4 Electrical System R Battery Diagram Sheet 1 Fig 4 16 1...
Страница 163: ...4 17 Section 4 Electrical System 370 Outrage R Section 4 Electrical System Battery Switch Panel Sheet 2 Fig 4 17 1...
Страница 164: ...4 18 370 Outrage Section 4 Electrical System R Helm Breaker Panel Sheet 3 Fig 4 18 1...
Страница 165: ...4 19 Section 4 Electrical System 370 Outrage R Section 4 Electrical System Helm Switch Panel Sheet 4 Fig 4 19 1...
Страница 166: ...4 20 370 Outrage Section 4 Electrical System R Bait Prep Station Switch Panel Sheet 5 Fig 4 20 1...
Страница 167: ...4 21 Section 4 Electrical System 370 Outrage R Section 4 Electrical System Lighting Schematic Deck Sheet 6 Fig 4 21 1...
Страница 168: ...4 22 370 Outrage Section 4 Electrical System R Windlass Schematic Sheet 7 Fig 4 22 1...
Страница 170: ...4 24 370 Outrage Section 4 Electrical System R DC Distribution Panel Sheet 9 Fig 4 24 1...
Страница 171: ...4 25 Section 4 Electrical System 370 Outrage R Section 4 Electrical System DC Wiring Schematic Cabin Sheet 10 Fig 4 25 1...
Страница 172: ...4 26 370 Outrage Section 4 Electrical System R Hardtop Scematic Sheet 11 Fig 4 26 1...
Страница 173: ...4 27 Section 4 Electrical System 370 Outrage R Section 4 Electrical System Stereo Diagram Sheet 12 Fig 4 27 1...
Страница 174: ...4 28 370 Outrage Section 4 Electrical System R 120V 60Hz Shore Power Schematic Sheet 13 Fig 4 28 1...
Страница 176: ...4 30 370 Outrage Section 4 Electrical System R 220V 50Hz Shore Power Schematic Sheet 15 Fig 4 30 1...
Страница 178: ...4 32 370 Outrage Section 4 Electrical System R Bow Table Option Bow Thruster Schematic Sheet 17 Fig 4 32 1...
Страница 180: ...4 34 370 Outrage Section 4 Electrical System R Bilge Wiring Schematic Sheet 19 Fig 4 34 1...
Страница 182: ...4 36 370 Outrage Section 4 Electrical System R 12V 30 AMP receptacles Option Sheet 21 Fig 4 36 1...