
3-20
370 Outrage
Section 3 • Systems & Components Overview & Operation
R
The 345 Conquest is equipped with a waste disposal
system located in the head in the forward cabin. The
system is protected by the “VACUUM FLUSH”
breaker on the DC Breaker Panel in the aft starboard
side of the forward cabin. The breaker must be ON
for the system to function (See page 4-7).
The waste system includes a Vacu-Flush
®
toilet, a 20
Gal. (75.7 L) holding tank with vacuum pump and
a thru-hull vent.
Head System
Environmental Considerations
The Environmental Protection Agency (EPA)
standards state that in freshwater lakes, reservoirs,
impoundments whose inlets or outlets are such as
to prevent the ingress or egress by vessel traffi c
subject to this regulation, or in rivers not capable
of navigation by interstate traffi c subject to this
regulation, marine sanitation certifi ed by the United
States Coast Guard (U.S.C.G.) installed on vessels
shall be designed and operated to prevent the
overboard discharge of sewage, treated or untreated
or any other waste derived from sewage.
The EPA standards further state that this shall
not be construed to prohibit the carriage of Coast
Guard certified flow through treatment devices
which have been secured so as to prevent such
discharges. They also state that the waters where
a Coast Guard certifi ed marine sanitation device
permitting discharge is allowed include: Coastal
waters, Estuaries, The Great Lakes and Intercoastal
waterways, Freshwater lakes and Impoundments
accessible through locks and other fl owing waters
that are navigable interstate by vessels subject to
this regulation. (40CFR 140.3)
NOTICE
This boat is equipped with a direct overboard
discharge valve. Discharging of sewage
directly overboard is for use where approved
only. Damage to the system could occur if
the discharge seacock is not open during
operation.
Severe state and federal penalties are levied
for discharging raw sewage and solid waste
in waters where it is not permitted.
Demonstrating that you have disabled the
macerator by locking the system and/or
removing the seacock handle may avoid a
fi ne.
It is illegal for any vessel to dump plastic trash
anywhere in the ocean or navigable waters of
the United States.
NOTICE
Vacu-Flush
®
Head
The foot pedal at the base of
the toilet opens a mechanical
seal which allows a vacuum
to force waste through the
opening in the bowl to the
vacuum generator, through
the vacuum pump and then to
the holding tank.
Operation
• Turn ON the FRESH WATER PUMP
breaker (See page 4-7)
• Turn ON the HEAD breaker
(See page 4-7)
• If there is no water in the bowl, lift the foot
pedal to add suffi cient water.
• To fl ush, depress the foot pedal until bowl is
clear.
Waste from the head is directed into the 10 gal.
(37.8 L) holding tank located in the bilge. A holding
tank fl uid level indicator is located on the overboard
discharge panel (See fi gure 3.20.2) which is located
on the starboard wall of the cabin. When the FULL
light is on, the holding tank must be emptied before
the head can be reused. However, it would be a good
practice to empty the tank when the 3/4 light is on
to avoid damage to the system.
NOTICE
NEVER use residential tissue paper in your
marine waste system.
Содержание 370 Outrage
Страница 2: ......
Страница 20: ...xx 370 Outrage R THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 146: ...3 66 370 Outrage Section 3 Systems Components Overview Operation R THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 162: ...4 16 370 Outrage Section 4 Electrical System R Battery Diagram Sheet 1 Fig 4 16 1...
Страница 163: ...4 17 Section 4 Electrical System 370 Outrage R Section 4 Electrical System Battery Switch Panel Sheet 2 Fig 4 17 1...
Страница 164: ...4 18 370 Outrage Section 4 Electrical System R Helm Breaker Panel Sheet 3 Fig 4 18 1...
Страница 165: ...4 19 Section 4 Electrical System 370 Outrage R Section 4 Electrical System Helm Switch Panel Sheet 4 Fig 4 19 1...
Страница 166: ...4 20 370 Outrage Section 4 Electrical System R Bait Prep Station Switch Panel Sheet 5 Fig 4 20 1...
Страница 167: ...4 21 Section 4 Electrical System 370 Outrage R Section 4 Electrical System Lighting Schematic Deck Sheet 6 Fig 4 21 1...
Страница 168: ...4 22 370 Outrage Section 4 Electrical System R Windlass Schematic Sheet 7 Fig 4 22 1...
Страница 170: ...4 24 370 Outrage Section 4 Electrical System R DC Distribution Panel Sheet 9 Fig 4 24 1...
Страница 171: ...4 25 Section 4 Electrical System 370 Outrage R Section 4 Electrical System DC Wiring Schematic Cabin Sheet 10 Fig 4 25 1...
Страница 172: ...4 26 370 Outrage Section 4 Electrical System R Hardtop Scematic Sheet 11 Fig 4 26 1...
Страница 173: ...4 27 Section 4 Electrical System 370 Outrage R Section 4 Electrical System Stereo Diagram Sheet 12 Fig 4 27 1...
Страница 174: ...4 28 370 Outrage Section 4 Electrical System R 120V 60Hz Shore Power Schematic Sheet 13 Fig 4 28 1...
Страница 176: ...4 30 370 Outrage Section 4 Electrical System R 220V 50Hz Shore Power Schematic Sheet 15 Fig 4 30 1...
Страница 178: ...4 32 370 Outrage Section 4 Electrical System R Bow Table Option Bow Thruster Schematic Sheet 17 Fig 4 32 1...
Страница 180: ...4 34 370 Outrage Section 4 Electrical System R Bilge Wiring Schematic Sheet 19 Fig 4 34 1...
Страница 182: ...4 36 370 Outrage Section 4 Electrical System R 12V 30 AMP receptacles Option Sheet 21 Fig 4 36 1...