XDL120 | User Manual
14 | 25
Data subj ect to change without notice
Bosch Connected Devi ces and Sol utions
response time is longer which is
dependent on filter coefficient
selection
Over-
Sampling:
Temperature/
Pressure/
Humidity
<oversamp_temperature>
<oversamp_pressure>
<oversamp_humidity>
Skipped
1X
2X
4X
8X
16X
0x00
0x01
0x02
0x03
0x04
0x05
Parameter to configure how often
the sensor values during a
sampling period are sampled from
the sensor
Oversampling setting is used to
reduce noise
Table 7: Sensor parameters for BMG160
Sensor
parameter
Tag in XML
file
Possible setting
XML hex
value
Notes
Bandwidth
<gyro_bw>
500 Hz
230 Hz
116 Hz
47 Hz
23 Hz
12 Hz
64 Hz
32 Hz
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
Range
<gyro_range> RANGE_2000
RANGE_1000
RANGE_500
RANGE_250
RANGE_125
0x00
0x01
0x02
0x03
0x04
Table 8. Sensor parameters for MAX44009
Sensor
parameter
Tag in XML file
Possible setting
XML hex
value
Notes
Integration
Time
<integration_time>
800 ms
400MS
200MS
100MS
50MS
25MS
12.5ms
6.25ms
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
The integration time is a time window
during which a pulse is measured.
800ms - This is a preferred for
boosting low-light sensitivity.
100ms - for high brightness.
6.25ms-50ms for manual mode only.
Note: In automatic mode (MANUAL
= 0), integration
time is automatically selected by the
on-chip algorithm to
be either
100ms/200ms/400ms/800ms
Output Data
Rate
<odr>
0.1 Hz,
0.2 Hz,
....,
25 Hz
0x00
0x01
….
0xf9
Output data rate setting with
resolution of 0.1 Hz.
Note: Continuous mode is
independent of the manual mode
setting
Continuous
Mode
<continuous_mode>
DISABLE
ENABLE
0x01
0x00
Select the continuous mode
configuration.
Manual
Configuration
DISABLE
ENABLE
0x01
0x00
currently unused, recommended to
keep DISABLE
Current
Devision Ratio
<cdr>
NORMAL_BRIGHTNESS
HIGH_BRIGHTNESS
0x00
0x01
Division ratio used to divide the
photo diode current.