XDL120 | User Manual
13 | 25
Data subj ect to change without notice
Bosch Connected Devi ces and Sol utions
08 Hz
15 Hz
20 Hz
25 Hz
30 Hz
0x03
0x04
0x05
0x06
0x07
Repetitions on
X and Y axes
<rep_xy>
rep_xy
repetitions X and Y
nXY = 1 + 2 * repXY
Repetitions are the number of measured
points to generate one sample, the more
repetitions the higher the measurement
accuracy.
Repetitions on
the Z axis
<rep_z>
Repetitions Z
nZ = 1 + repZ
Related to Z-Axis
Table 5: Sensor parameters for BMA280
Sensor
parameter
Tag in XML
file
Possible
setting
XML hex
value
Notes
Bandwidth
<accel_bw>
7.81 Hz
15.63 Hz
31.25 Hz
62.50 Hz
125 Hz
250 Hz
500 Hz
0x00
0x01
0x02
0x03
0x04
0x05
0x06
Bandwidth parameter is used to set the output data
rate of the acceleration sensor.
Range
<accel_range>
2G
4G
8G
16G
0x00
0x01
0x02
0x03
Table 6: Sensor parameters for BME280
Sensor
parameter
Tag in XML file
Possible setting
XML
hex
value
Notes
Output Data
Rate
<odr>
0.1 Hz,
0.2 Hz,
....,
25 Hz
0x00,
0x01,
….
0xf9
Output data rate setting resolution
of 0.1 Hz.
Power Mode
<power_mode>
SLEEP_MODE
FORCED_MODE
NORMAL_MODE
0x00
0x01
0x03
The environmental sensor can
operate in three different modes:
sleep, forced and normal.
Standby
Duration
<standby_dur>
1MS
63MS
125MS
250MS
500MS
1000MS
2000MS
4000MS
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
The standby duration is the amount
of time the sensor is in idle state.
The possible standby times range
from 1ms to 4 s.
Note: The measurement rate
in normal mode depends on
the measurement time and
the standby time
Filter
Coefficient
<filter_coeff>
COEFF_OFF
COEFF_2
COEFF_4
COEFF_8
COEFF_16
0x00
0x01
0x02
0x03
0x04
Controls the time constant of the
filter.
The response time depends on the
filter coefficient selected.
Note: The number of samples will
increase if the