background image

GSM-R4-DIN_EN (Version 1.02; 2016-04-06) 

 

Page #1 of 5 

GSM-R4-DIN, GSM-R4-DINB 

1.

 

Introduction 

 

The 

GSM-R4-DIN

  and 

GSM-R4-DINB

 (

GSM

 rele

4

 for short) 

are  designed to  be 

mounted  on  a  DIN  rail  into  a  switchboard.

   

GSM

 rele

4

  can  control  two 

independent  electrical  circuits  in  a  building  e.g.  circuit  of  an  accumulator  stove  and 
circuit for garage gate control. The control is made via SMS messages or by ringing. 

After installation into an electrical box insert a SIM card of any GSM operator and the 

device is ready to operate.  
 

GSM

 rele

4

  has 

2 galvanically  isolated  digital  outputs

  with  a  semiconductor 

switch, which can control directly low power circuits up to 230V

AC

/90mA. It’s possible 

to control directly e.g. a thermoregulator circuit of a gas boiler or a coil of one phase 

contactor  230V  AC.  The  contact  of  the  contactor  can  then  control  either  one  phase 
high power appliance (e.g. electrical radiator) or a coil of three phase contactor of an 

accumulation stove. 
 

GSM

 rele

4

  has  also 

2  analog  inputs 

for  temperature  measuring  and 

2  digital 

inputs

 which can be activated by a contact from 4V power provided by 

GSM

 rele

4

 or 

by  an  external  voltage  3  to  30V DC. 

GSM

 rele

4

  has  built  in  two 

automatic 

regulators

  which  use  analog  inputs  from  temperature  sensors  to  maintain  preset 

temperature. The temperature of sensors can be readout via SMS. 

 
There is an internal 

built in Li-Ion accumulator

 which enables to send an SMS in 

case of a power failure and to restore the output status after a power failure. It’s also 

possible  to  monitor  the  status  of  inputs  and  temperatures  via  SMS  during  230 V

AC

 

power failure. 
 
(1) OUTPUT 3, 4 (Y3, Y4) connectors 

(2) Pushb LED (Y3, Y4) 

(3) INPUT 1, 2 (X1, X2) LED  
(4) INPUT 1, 2 (X1, X2) connectors  

(5) DIN rail holder 
(6) Temperature sensors connector (T5, T6) 

(7) USB connector (for configuration) 

(8) 

GSM

 rele

4

 operation state LED indicators 

(9) 230V

AC

 Power supply connector 

(10) SIM card and MicroSD card holder  
(11) External GSM antenna connector 

( - ) Temperature sensor GSM-C-T2 
 

 

2.

 

Package Content 

1 pc 

GSM

 rele

4

 (order code 

GSM-R4-DIN

 or 

GSM-R4-DINB

)   

1 pc  GSM antenna ANT05S 

1 pc  temperature sensor GSM-C-T2 (based on KTY81-210), cable - 1 meter  

1 pc  cable USB 2.0 A-B, 1.8m (order code HW-11.02.8818) 
1 pc  connector 5.00 mm  

2 pcs  connector 3.81 mm 
1 pc  connector 3.81 mm 

1 pc  connector 3.81 mm 

1 pc  screwdriver 2 mm 
1 pc  printed documentation 

 

3.

 

Installation 

1.

 

To operate the 

GSM

 rele

4

 a SIM card of any GSM operator is necessary. SIM card 

must  be functional and  active. Also some credit is necessary if  SIM card is  pre-

paid. We recommend to deactivate the PIN code for installation.  

2.

 

Insert this prepared SIM card (cut off corner first) into a slot on the side of the 

GSM

 rele

4

. The SIM card holder is located in a slot on side of 

GSM

 rele

4

 (close to 

GSM antenna connector). The proper insertion is indicated by a slight mechanical 
click  noise.  To  remove  the  SIM  card  -  press  the  SIM  card  in  direction  into  the 

GSM

 rele

4

 until mechanical click. The SIM card can be the freely removed.  

3.

 

Now  it’s  possible  to  connect  the  device  to  230V  AC  power  supply.  If  the  power 
supply  is  correct,  green  LED  diode 

POWER  SUPPLY

  goes  on.  After  about  20 

seconds, blue LED diode GSM starts flashing with a period 1 per 3 sec.  

4.

 

For  the  first  tests  of 

GSM

 rele

4

  the  connection  of  inputs  and  outputs  is  not 

important.  Please  keep  in  mind  that  the  devices  connected  to  OUTPUTS  will  be 
switched on during tests!  

5.

 

To  test  the 

GSM

 rele

4

  press  the  pushbutton  bellow  OUTPUT  3.  The  green  LED 

diode  for  OUTPUT 3  lights  ON.  Send  an  SMS  from  mobile  phone  (which  will  be 
mainly  used  to  control  the 

GSM

 rele

4

)  in  form 

1234 Y3 OFF

  to  the  telephone 

number  of  the  SIM  card  inserted  into  the 

GSM

 rele

4

.  This  will  switch  off  the 

plugged appliance. The green status LED for OUTPUT3 goes OFF. Simultaneously, 

the  device  automatically  sends  a  confirmation  SMS  message  on  performing  the 

operation.  The  password  1234  can  be  changed  later  in  configuration.  The 

GSM

 rele

4

  reacts  on  the  SMS  text  message  from  any  telephone  as  long  as  the 

access  password  matches.  The  very  first  one  (the  sender  of  the  first  valid  SMS 
message) will be remembered as master and will receive messages about events 

on 

GSM

 rele

4

. This user can also control OUTPUT 4 by “ringing” on the device. 

6.

 

Try “ringing” on device. You can make pulse on OUTPUT 4 for approx. 4 seconds 

by calling to 

GSM

 rele

4

 (with default factory setting). The device hangs up the call 

and  makes  pulse  on  the  OUTPUT 4.  This  pulse  can  be  used  for  example  for 
opening entrance gate. To test this function call from the phone (which was used 

to send the first test SMS to switch off the OUTPUT 3). The pulse is indicated by 
green LED. 

7.

 

Try regulation. You can send SMS in form of 

1234 Y3 REG 25

 to command the 

device to maintain temperature to 25°C. The range of regulation is between 0°C 
and +55°C. Regulation can be canceled by SMS with command 

1234 Y3 OFF

. By 

default the regulation of OUTPUT 3 depends on temperature sensor connected to 
analog INPUT T5 (OUTPUT 4 depends on INPUT T6). 

8.

 

A default  factory setting of the 

GSM

 rele

4

 can be recovered by  an SMS in  form 

1234 FACTORY. 

Your setting can be then restored from backup configuration of 

SeaConfigurator

 program. 

 

4.

 

Technical specifications 

Parameter 

Symbol 

MIN. 

TYP. 

MAX. 

Unit 

Dimensions 

Width 

Š 

 

71 

 

mm 

Height 

 

90 

 

mm 

Depth 

 

58 

 

mm 

Power  

supply 

*1)

 

Voltage 

180 

230 

250 

V AC 

Current 

 

 

11 

30 

mA 

Digital inputs 

INPUT1, INPUT2 

Voltage 

V

IN

 

12 

30 

V DC 

Current 

I

IN

 

 

3,5 

 

mA DC 

Digital 

outputs 

OUTPUT3, OUTPUT4 - Semiconductor switch OPTO-MOS 

Voltage 

V

OUT

 

230 

260 

(400) 

V AC 

(V DC) 

Current 

I

OUT

 

 

 

90 

 (120) 

mA AC 

(mA DC) 

Analog inputs 

2 x temperature sensor GSM-C-T2, Accuracy in range 0 to 30°C ... 1°C 

Temperature 

-30 

 

+55 

°C 

Temperature 

Storage 

without supply 

 

 

 

*2)

 

Months 

Operational 

tA 

-20 

 

+45 

°C 

Use 

GSM

 rele

4

 - DIN inside the rack with IP44 or better!

*1)

 Use breaker max. 10 A before 

GSM

 rele

4

. For power supply 230V

AC

 use lines min. 

1 mm

2

*2)

 The 

GSM

 rele

4

 has to be connected to 230V

AC

 power supply every 3 months for 

24 hours (due to internal accumulator). 

 

 

5.

 

Hardware 

The  front  panel  of  the 

GSM

 rele

4

 

contains  a set of status indicating LED 
diodes  located,  pushbuttons  for  local 

control  of  outputs,  connectors  for 
connecting power supply, input signals, 

output 

signals 

and 

temperature 

sensors. 
  

5.1

 

Connectors 

GSM

 rele

4

  enables  to  connect  2 

external digital inputs, 2 external digital 

outputs  and  2  external  temperature 
sensors  GSM-C-T2  with  temperature 

range from -30°C to +55°C. 
The line length of a connected external 

temperature  sensor  is  not  limited  but 

the wire has a certain resistance which 
influences the measured temperature (16   means 1 °C). 
The recommended type of relay for connection of more appliances is GSM-RELE-OUT.  
When using the 

GSM

 rele

4

 for a gate control by a phone ring, it’s possible to connect 

output 3 and COM directly with a pushbutton of the gate control. 
Read 

Technical  specifications

  before  connecting  external  devices!  Don’t  overload 

inputs and outputs. 
Examples of connection of 

GSM

 rele

4

 are placed later in this text. 

 
 

5.2

 

Pushbuttons 

The 

GSM

 rele

4

  has  two  pushbuttons  for  local  control  of  outputs.  Every  press  of  the 

pushbutton changes the state of the output.  
 

Before inserting the SIM card into the 

GSM

 rele

4

 device, we 

recommend to turn off setting of the “PIN code”! 

Insert  the  active  SIM  card  (=  at  least  one  call  was  made)  to  any  mobile 
telephone and turn off the requirement of setting the PIN. On most mobile 

telephones,  this  option  can  be  found  in  menu  “Setting  the  telephone 

protection”. or “Setup -> Security -> PIN control”. 

ATTENTION:   

GSM

 rele

4

 must be mounted by qualified personnel only! 

X2 4V

X1

230 V

AC

GND

POWER
ERROR

GSM 

rele

4

3

4

ALARM

GSM

1

2

1 2 3

4 5

6

GSM

 ANT.

Y3

Y4

T5

T6

1 2 3

4

1 2

1 2

1

2

L1

N

EXT

USB

SIM,
uSD

3

1

2

8

9

6

11

4

7

5

5

10

Содержание GSM-R4-DIN

Страница 1: ...FF Simultaneously the device automatically sends a confirmation SMS message on performing the operation The password 1234 can be changed later in configuration The GSM rele4 reacts on the SMS text message from any telephone as long as the access password matches The very first one the sender of the first valid SMS message will be remembered as master and will receive messages about events on GSM r...

Страница 2: ...ndicated CODE ADD Password e g 1234 New user with specified password is added password max 20 digits If the password already exists an error is indicated If the password already exists and the user is disabled the user is activated and no error is indicated CODE DIS Password e g 9876 A disabled flag for the user is set If the user is not in the list an error is indicated CODE CHANGE Passwords e g ...

Страница 3: ...e is listed in parentheses e g Credit 243 15 Kc Example of status SMS Explanation Base station Y3 REG 25 27 C OK Device name Command confirmation Y3 REG27 X1 ON INPUT 1 state X2 ON INPUT 2 state Y3 ON REG 25 27 C OUTPUT 3 state Y4 OFF OUTPUT 4 state T5 25 C INPUT T5 actual temperature T6 26 C INPUT T6 actual temperature Power Failure Power supply from 230VAC from battery Signal 38 GSM signal level...

Страница 4: ...ect the temperature sensors Outputs of the GSM rele4 control contactors of heater and boiler VF 1 2 3 4 5 6 1 2 3 4 1 2 1 2 NAPÁJENÍ GSM GSM RELÉ 2 DIN VÝSTUP VSTUP 1 2 3 4 1 2 3 4V t1 t2 Contactor 1 230V AC PE N L Contactor 2 L N PE BOILER L 1 2 3 4 5 6 1 2 3 4 POWER GSM RELE4 DIN OUTPUT 3 4 T5 T6 1 1 2 1 2 1 ALARM GSM INPUT 1 2 GSM Breaker 2 1 τ τ Tempe rature sensors External supply 12V DC Y3 N...

Страница 5: ... to send a receive SMS message Switch off using PIN on a SIM card Cancel all call redirection for a SIM card Ask your mobile operator for help if necessary New SIM card has to be activated Ask your mobile operator for help if necessary Check credit on a pre paid SIM card Ask your mobile operator for help if necessary LED GSM blue is off dark LED ERROR red is on lights permanently Weak poor GSM sig...

Отзывы: