Command 

This  part  of  a  message  specifies  a  requested  action.  See  the  following  table  for 

available  commands. 

GSM

 rele

4

  commands  are  not  a  case  sensitive,  it’s  possible  to 

use upper letters as well as lower letters. 

Command 

Parameter 

Meaning 

Y3 ON 

An OUTPUT 3 will be switched on. 
(Use Y4 ON for OUTPUT 4) 

ON 

This command acts in exactly the same way as 
command ON3 

Y3 OFF 

3 or 4 

An OUTPUT 3 will be switched off. 
(Use V4 OFF for OUTPUT 4) 

OFF 

 

This command acts in exactly the same way as 
command OFF3 

Y3 PULSE 
Y3 RESET 


 

Generates 4 sec pulse on OUTPUT 3 
Generates 4 sec reset on OUTPUT 3 

PULSE 
RESET 

 

These commands act in exactly the same way as 
command PULSE3 / RESET3. 

REG 

0 to 55 

Setting of requested temperature and starts 
regulation mode. 

STATE 

Request of status SMS (state of inputs, outputs, 
temperatures, signal quality and credit). 

 

Tip:

 It’s possible to use more commands in one SMS. Commands are separated by a 

space (see an example). 
 
Examples: 

1234 ON

   

… an appliance connected to OUTPUT3 will be switched on 

1234 Y3 ON

 

… an appliance connected to OUTPUT3 will be switched on 

1234 Y4 ON

 

… an appliance connected to OUTPUT4 will be switched off 

1234 Y4 PULSE 5

  … an OUTPUT 4 will be switched on and then after  5 seconds 

will be switched off (Notes: if an output is already switched on, it will be just switched 

off after 5 seconds) 

1234 Y4 REG 5

 

…  requested  temperature  for  the  function  temperature 

regulation of OUTPUT 4 will be set to + 5°C 
 
an example of more commands in one SMS: 

1234 Y3 OFF Y4 REG 25 

… An OUTPUT 3 will be switched off and the requested 

temperature will be set to 25°C  
 
Confirmation 
If a command message contains a valid password (access code) the 

GSM

 rele

4

 returns 

a confirmation message which informs if a command was accepted (see chapter Status 
SMS). If you don’t want a confirmation message (e. g. when sending a command SMS 

from the Internet GSM gates) add a command “NOBACK”. 
 

Command 

Meaning 

NOBACK 

No confirmation SMS will be sent 

Example: 

1234 Y3 ON NOBACK

    

…  an  appliance  connected  to  OUTPUT3  will  be 

switched on. NO status message will be sent back 
 

7.3

 

Local control using pushbuttons 

GSM

 rele

4

 has 2 pushbuttons for local control of outputs (see. Chapter 5.2) 

 

7.4

 

Status SMS message 

Whenever the command SMS contains valid password the 

GSM

 rele

4

 send back Status 

message.  
Parameter  Credit  is  sent  only  in  case  of  pre-paid  SIM  cards.  If  the  actual  value  of 

Credit cannot be readout from operator, the last known value is listed in parentheses 

e.g. Credit=(243.15 Kc). 
 

Example of status SMS 

Explanation 

Base station:  Y3 REG 25/27'C OK; 

Device name:  

Command confirmation: Y3 REG27 

X1=ON 

INPUT 1 state  

X2=ON 

INPUT 2 state 

Y3=ON(REG 25/27'C) 

OUTPUT 3 state 

Y4=OFF 

OUTPUT  4 state 

T5=25'C 

INPUT  T5  actual temperature 

T6=26'C 

INPUT  T6  actual temperature 

Power=Failure 

Power supply from 230V

AC

 / (from battery) 

Signal=38% 

GSM signal level 

Credit=243.15 Kc 

Credit on pre-paid SIM card 

 

7.5

 

Remote Control via the application for OS 
Android 

The application for OS Android called 

SeaControl

 is used for control and monitoring 

of GSM RELAY, you can download it for free. For detailed information and downloading 
the application, go to www.seapraha.cz and write GSM-CONTROL into the searchbox. 

This application communicates with a GSM relay via SMS. 
 

 
 

8.

 

Warranty 

General  warranty  period  is  12  months  after  purchase,  when  eventual  malfunction 

device will be repaired free of charge in SEA company while shipping to SEA is paid by 

customer  and  SEA  pays  for  shipping  back  to  customer.  For  SW  there  is  24  months 
warranty under following conditions: 
Both  CPU  and  PC  software  is  sold  “as  is”.  The  software  was  created  by  the  best 
software  engineers  in  SEA  and  was  carefully  tested  both  in  SEA  and  also  by  SEA 

customers  using  GSM  applications  products  made  in  SEA.  In  spite  of  making  all 
possible  to  get  error  free  software  it  can  happen,  that  the  software  in  CPU  or  PC 

programming    SW    or  their  mutual  interaction  has  some  error  under  some  specific 

conditions. If such error is found and the description of the problem 
including configuration file is sent by E-mail to SEA ltd., the error is 

removed  free  of  charge  and  SEA  will  send  new  SW  by  E-mail  to 
customer. 
SEA ltd. has NO  RESPONSIBILITY  for  any  damage, lost, costs and 

any other problems direct or inducted, caused by such SW error, by 
eventual device malfunction from any reason or by undelivered SMS 

from the device. 
 
 

CE Declaration of conformity 

in accordance with the Radio and Telecommunications Terminal Equipment Directive 1999/5/EC (R&TTE) and Directive 
2011/65/EU (ROHS). 

We 

SEA, spol. s r.o., Dolnoměcholupská 1537/21, CZ 102 00 Praha 10, Czech Republic, 

ID

: 47117931 (

manufacturer

)

 

declare under our sole responsibility, that  product  

device for remote control and monitoring 

type   

GSM-R4-DIN

 

is in conformity with the following standards:

 

health and safety: 

EN 60 950-1:2005+A1:2009 EN 60 950-1:2006+A11:2009+A1:2010+A12:2011 

EMC: 

 

ETSI EN 301 489-1 

ETSI EN 301 489-7 v1.3.1 

radio frequency: 

EN 301 511 v 9.0.2 

 

The last two digits of year in which the CE marking was affixed:

 

     14 

  

Place of issue: 

Praha

 

Name: 

Ing. Mario Vejlupek

 

Date of issue: 

18.12.2014 

Grade: 

Technical director 

 

Содержание GSM-R4-DIN

Страница 1: ...FF Simultaneously the device automatically sends a confirmation SMS message on performing the operation The password 1234 can be changed later in configuration The GSM rele4 reacts on the SMS text message from any telephone as long as the access password matches The very first one the sender of the first valid SMS message will be remembered as master and will receive messages about events on GSM r...

Страница 2: ...ndicated CODE ADD Password e g 1234 New user with specified password is added password max 20 digits If the password already exists an error is indicated If the password already exists and the user is disabled the user is activated and no error is indicated CODE DIS Password e g 9876 A disabled flag for the user is set If the user is not in the list an error is indicated CODE CHANGE Passwords e g ...

Страница 3: ...e is listed in parentheses e g Credit 243 15 Kc Example of status SMS Explanation Base station Y3 REG 25 27 C OK Device name Command confirmation Y3 REG27 X1 ON INPUT 1 state X2 ON INPUT 2 state Y3 ON REG 25 27 C OUTPUT 3 state Y4 OFF OUTPUT 4 state T5 25 C INPUT T5 actual temperature T6 26 C INPUT T6 actual temperature Power Failure Power supply from 230VAC from battery Signal 38 GSM signal level...

Страница 4: ...ect the temperature sensors Outputs of the GSM rele4 control contactors of heater and boiler VF 1 2 3 4 5 6 1 2 3 4 1 2 1 2 NAPÁJENÍ GSM GSM RELÉ 2 DIN VÝSTUP VSTUP 1 2 3 4 1 2 3 4V t1 t2 Contactor 1 230V AC PE N L Contactor 2 L N PE BOILER L 1 2 3 4 5 6 1 2 3 4 POWER GSM RELE4 DIN OUTPUT 3 4 T5 T6 1 1 2 1 2 1 ALARM GSM INPUT 1 2 GSM Breaker 2 1 τ τ Tempe rature sensors External supply 12V DC Y3 N...

Страница 5: ... to send a receive SMS message Switch off using PIN on a SIM card Cancel all call redirection for a SIM card Ask your mobile operator for help if necessary New SIM card has to be activated Ask your mobile operator for help if necessary Check credit on a pre paid SIM card Ask your mobile operator for help if necessary LED GSM blue is off dark LED ERROR red is on lights permanently Weak poor GSM sig...

Отзывы: