5.3

 

LED diodes 

The  front  panel  of 

GSM

 rele

4

  contains  indication  LED  diodes  POWER,  ALARM,  GSM, 

EXT  and  LED  diodes  which  indicates  status  of  digital  inputs  (INPUT1,  INPUT2)  a 

outputs (OUTPUT3, OUTPUT4).  
 

 
 

5.4

 

Battery 

GSM

 rele

4

 is equipped with backup 3.7 V Li-Ion battery which enables to operate the 

GSM

 rele

4

 for several hours in normal mode in case of  a 230 V

AC

 power failure. (the 

battery  life  time  depends  on  mode  of  usage).  During  the  battery  supply  mode  the 

GSM

 rele

4

 the 

LED POWER

 blinks at an interval of 1 for 3 seconds. 

 

*)  When  the  battery  falls  below  a  certain  voltage,  the  device  switches  to  "Sleeping 

mode", in which it can stay up to a month. The 

GSM

 rele

4

 wakes up of the sleeping 

mode, either by applying 230V AC power supply or by change of the logic INPUT 1 or 

INPUT 2.   

 

*) Not used in this version 

 

 

5.5

 

External antenna connector 

GSM

 rele

4

 is supplied with an external antenna GSM-ANT05S. It is not recommended 

to put this type of antenna on metal surface (the signal quality will degrade). 
If a 

GSM

 rele

4

 is used in area with a low GSM signal, it’s possible to use another type 

of the antenna with higher gain. 
 

5.6

 

MicroSD card and data logging 

GSM

 rele

4

 (version GSM-R4-DIN) can store detailed information of its activities into a 

log file on a MicroSD card for later analysis. The MicroSD card reader is located under 

the removable cover close to the SIM card reader.  
Note: This function requires a license - ask your supplier for details. 
 

6.

 

Configuration 

Configuration of the 

GSM

 rele

4

 can be made in several ways. 

 

6.1

 

GSM

 rele

4

 - default factory configuration 

When  the  signal  on  INPUT 3  or  INPUT 4  changes,  the 

GSM

 rele

4

  sends  an  SMS 

message to the main users (to the telephone number from which it received the first 
valid command).  The  input signal must be stable  for certain time  (approx. 1 sec) to 

avoid sending unwanted SMS messages in case of interference on the input.  
Temperature regulators are set up so that the OUTPUT 3 is regulated by temperature 

sensor on INPUT T5 and OUTPUT 4 from the temperature sensor on INPUT T6. 
 

6.2

 

Configuration of 

GSM

 rele

4

 from PC via USB 

The configuration (parameter setting) can be done using program 

SeaConfigurator

.  

E.g. 

GSM

 rele

4

 can be set to inform of  the 230V AC  power  failure or restoration via 

SMS or by ringing.  
 

SeaConfigurator

 can be downloaded on the web page: 

http://www.seapraha.cz

 

Fill in the word 

GSM-R4-DIN

 or 

GSM-R3-DINB

 to the search field. 

 

6.3

 

Configuration of 

GSM

 rele

4

 via SMS 

Some parameters of 

GSM

 rele

4

 can be configured via SMS: 

List of configuration SMS commands: 
 

Command 

Parameter 

Meaning 

FACTORY 

All parameters are setup to factory default. 

USER DIS 

Phone number e.g.: 
 +420777777447 

A “disabled” flag for the user is set. If and user is 
not in the list an error is indicated. 

USER CHANGE 

Phone numbers 
e.g.: 

+420777777447 
+420123456789 

The first phone number in the list is replaced by 
the second number. If the first phone number 

does not exist in the list or the second is already 
in the list an error is indicated. 

CODE ADD 

Password 

e.g. 

 1234 

New user with specified password is added 
(password max. 20 digits).  If the password 

already exists an error is indicated.  If the 

password already exists and the user is disabled, 
the user is activated and no error is indicated. 

CODE DIS 

Password e.g.: 
 9876 

A “disabled” flag for the user is set. If the user is 
not in the list an error is indicated. 

CODE CHANGE 

Passwords 

e.g. 

1234  9876  

The first password in the list is replaced by the 
second password. If the first password does not 

exist in the list or the second is already in the list 
an error is indicated. 

 

1234 FACTORY 

… All parameters of 

GSM

 rele

4

 will be setup up to factory default

 

1234 USER DIS +420777777497  
… the user with phone 420777777497 is disabled 
1234 USER 420777420777777451  
… the phone user’s number is changed from +420777777497 to +420777777451 
 

1234 CODE ADD 9876 

… the new password 9876 is added 

1234 CODE DIS 9876 

… the password 9876 is disabled 

1234 CODE CHANGE 1234 9876  
… the first password 1234 is changed to new second password 9876 

 

7.

 

GSM rele

4

 - Control 

7.1

 

Output control by “ringing” 

GSM

 rele

4

 is set by the manufacturer to switch ON an OUTPUT 4 for 4 seconds when 

any user from the list of users calls to 

GSM

 rele

4

 phone number. This pulse is useful 

for an opening of an entry gate. Test this function by a call to 

GSM

 rele

4

 from your 

mobile  phone  (it’s  important  to  send  a  valid  command  SMS  to 

GSM

 rele

4

  from  your 

mobile phone if have inserted a “new” SIM card to 

GSM

 rele

4

). 

GSM

 rele

4

 rejects a call and at the same time generates a pulse on an OUTPUT 4.  

 

7.2

 

Remote control of 

GSM rele

4

 via SMS 

GSM

 rele

4

 is controlled via SMS of the GMS network. Text SMS are in form: 

 

<PASSWORD> <COMMAND> [<COMMAND >] 

 

Each  command  is  preceded  by  Yn,  where  n  is  the  number  of  controlled  output.  If 
output  is  not  specified,  the  OUTPUT 3  (Y3)  is  used  as  default.  Commands 

ON

  and 

Y3 ON

 and 

Y3ON

 has the same meaning. 

 
Example: 

1234 Y3 ON 

…  an  appliance  connected  to  OUTPUT 3  will  be  switched  on, 

confirmation message will be sent back 

1234 Y4 OFF NOBACK 

… an appliance connected to OUTPUT 4 will be switched off, 

NO confirmation message will be sent back 

Password (access code) 

Password is a main security item for 

GSM

 rele

4

 control. Command SMS are accepted 

from any phone number. It means anybody who knows the password and the phone 

number can control the 

GSM

 rele

4

. The password is a string of digits (1 to 20) which 

must be on the beginning of any command SMS. Otherwise the SMS will be ignored. A 

text before the password is automatically ignored. It is useful when command SMS are 

sent from Internet GSM gates.  
 
 
Factory setting of a password is: 
 

1234 

LED 

COLOR 

Meaning 

Dark 

Light 

Blink 1 per 3sec 

1:1 

EXT 

orange  - 

SUPPLY 

green 

Device 

switched off 

Supplied 
from 

230VAC 

Supplied from  
battery, 

NO 230VAC 

ERROR 

red 

Standard 

operation 

GSM error 

uSD card 

error 

ALARM 

red 

Function  

“Alarm” 
NOT active 

Any sensor 

activated 
ALARM! 

Function 

“Alarm” 
active 

Function 

“Alarm”  
preparation 

GSM 

blue 

no GSM signal  Other GSM 

error 

operational 

Fast: 
Connecting 

to GSM 

 
Slow:  

SIM card 
problem 

INPUT1 
INPUT2 

green 

Input not 
activated 

Input is 
activated 

OUTPUT3 

OUTPUT4 

green 

Output 

switched off 

Output 

switched on 

Inverse blinking 
during 

regulation 
mode 

 

Содержание GSM-R4-DIN

Страница 1: ...FF Simultaneously the device automatically sends a confirmation SMS message on performing the operation The password 1234 can be changed later in configuration The GSM rele4 reacts on the SMS text message from any telephone as long as the access password matches The very first one the sender of the first valid SMS message will be remembered as master and will receive messages about events on GSM r...

Страница 2: ...ndicated CODE ADD Password e g 1234 New user with specified password is added password max 20 digits If the password already exists an error is indicated If the password already exists and the user is disabled the user is activated and no error is indicated CODE DIS Password e g 9876 A disabled flag for the user is set If the user is not in the list an error is indicated CODE CHANGE Passwords e g ...

Страница 3: ...e is listed in parentheses e g Credit 243 15 Kc Example of status SMS Explanation Base station Y3 REG 25 27 C OK Device name Command confirmation Y3 REG27 X1 ON INPUT 1 state X2 ON INPUT 2 state Y3 ON REG 25 27 C OUTPUT 3 state Y4 OFF OUTPUT 4 state T5 25 C INPUT T5 actual temperature T6 26 C INPUT T6 actual temperature Power Failure Power supply from 230VAC from battery Signal 38 GSM signal level...

Страница 4: ...ect the temperature sensors Outputs of the GSM rele4 control contactors of heater and boiler VF 1 2 3 4 5 6 1 2 3 4 1 2 1 2 NAPÁJENÍ GSM GSM RELÉ 2 DIN VÝSTUP VSTUP 1 2 3 4 1 2 3 4V t1 t2 Contactor 1 230V AC PE N L Contactor 2 L N PE BOILER L 1 2 3 4 5 6 1 2 3 4 POWER GSM RELE4 DIN OUTPUT 3 4 T5 T6 1 1 2 1 2 1 ALARM GSM INPUT 1 2 GSM Breaker 2 1 τ τ Tempe rature sensors External supply 12V DC Y3 N...

Страница 5: ... to send a receive SMS message Switch off using PIN on a SIM card Cancel all call redirection for a SIM card Ask your mobile operator for help if necessary New SIM card has to be activated Ask your mobile operator for help if necessary Check credit on a pre paid SIM card Ask your mobile operator for help if necessary LED GSM blue is off dark LED ERROR red is on lights permanently Weak poor GSM sig...

Отзывы: