9.
Examples of connection
An example of usage
GSM
rele
4
. With two power outputs are controlled two electrical appliances such as heating and boiler with contactors, digital inputs detect voltage on
switching / opening a door contact and two analog inputs T5, T6 measure temperatures.
The schematics calculate with usage of the “Load Management Signal”. Logic input No. 1 is activated by supplying an external 12V DC logic input and input 2 uses internal 4V DC
and connects directly to the terminal door contact. The 2 analog inputs T5, T6 connect the temperature sensors. Outputs of the
GSM
rele
4
control contactors of heater and boiler.
VF
1
2
3
4
5
6
1
2
3
4
1
2
1
2
NAPÁJENÍ
GSM
GSM RELÉ 2 - DIN
VÝSTUP
VSTUP
1
2
3
4
1 2
3
4V
t1
t2
Contactor
1
230V
AC
PE
N
L
Contactor
2
L
N
PE
BOILER
L
1
2
3
4
5
6
1
2
3
4
POWER
GSM RELE4 - DIN
OUTPUT
3 4
T5
T6
1
1
2
1
2
1
ALARM
GSM
INPUT
1 2
GSM
Breaker
2
1
τ
τ
Tempe-
rature
sensors
External
supply
12V
DC
+
Y3
N
L
Antenna
L
N
PE
HEATING
HDO*)
Signal
from Load
Manage-
ment
Y4
X1
┴
X2
+
-
Electrical schematics
VF
L
N
PE
HEATING
L
N
PE
PE
BOILER
1
2
3
4
5
6
1
2
3
4
230V
AC
PE
N
L
POWER
GSM RELE 4 - DIN
OUTPUT
3 4
T5
T6
BREAKER
1
1
2
1
2
1
CONTACTOR
I
O
AUTO
I
O
ALARM
GSM
INPUT
1 2
CONTACTOR
I
O
AUTO
HDO
2
1
V1a
V1b
4V
V2b
V2a
GND
V3a
V3b
V4a
V4b
N
L
GSM
Antenna
HDO
*)
Signal
from
Load
Manage-
ment
Wiring