5 Starting aid
Comply with the instructions
of the vehicle manufacturer
and his supplier when char-
ging a battery in the vehicle
and when using the charger
as a starting aid!
1.
Switch off main switch (4).
2.
Set time switch (1) to charging
without time limitation
.
3.
Securely connect the charging
clips to the battery, ensuring that
the polarity is correct:
– red clip to positive terminal
– black clip to negative terminal
Make sure that the charging
clips are attached securely.
4.
Set selector switch (2) to
Rapid/Start
5.
Switch on main switch (4).
The maximum current is
applied when the charger is
switched on.
Therefore, the charger may
only be switched on immedia-
tely before the starting pro-
cess and must be switched
off immediately after the star-
ting process.
6.
Start the engine
Starting aid may only be given
for a max. 1 minute! Then
observe a cooling–down pe-
riod of approx. 25 minutes!
7.
Switch off main switch (4)
8.
Set selector switch (2) to
0
Off
9.
Remove the charging clips from
the battery.
6 Technical data
Dimensions L x W x H:
250 x 280 x 530 mm
Weight:
14 kg
Ambient temperature:
–10
C ... +40
C
Rated mains voltage:
230 V +6%/–10%
Rated mains frequency: 50...60 Hz
Power consumption:
approx. 1800 VA
Mains connection cable:
1.5 mm
2
/ 4,5 m
Rated battery voltage:
12/24 V
Charging current (4 stages) :
Normal charging
12 V
20 A
arithm.
/ 28 A
eff.
24 V
10 A
arithm.
/ 14 A
eff.
Rapid charging
12 V
40 A
arithm.
/ 56 A
eff.
24 V
20 A
arithm.
/ 28 A
eff.
Starting aid current for 1 V/cell:
12 V
130 A
arithm.
/ 150 A
eff.
24 V
100 A
arithm.
/ 125 A
eff.
Ammeter
0...100 A
arithm.
Charging characteristic:
W
Charging leads:
10 mm
2
/ 2,7 m / PVC
Thermostatic switch in the power
transformer
Degree of protection (DIN 40050):
IP 21
Safety class (DIN 40530):
I
RFI suppression
to VDE 0875
Radio interference
suppression
It is herewith certified that charger
WL 200 S is provided with a radio
interference suppressor in com-
pliance with the regulations of
EN 55014.
7 Faults
Charger does not
function after switching on:
1.
Switch off main switch (4).
2.
Set selector switch (2) to
0
Off
3.
Pull out the mains plug.
4.
Check the mains connection.
5.
Check the mains fuse:
6.
Check polarity:
– Red clip to positive terminal
– Black clip to negative terminal
7.
Check that the charging clips
are securely attached.
8.
Check the rated battery voltage.
9.
Check the automatic circuit–
breakers (4, 5).
The charger must be checked by the
after-sales service if it still does not
function.
8 After-sales service
Please contact an after-sales ser-
vice center for Bosch products if
spare parts or after-sales services
are required.
The list of Bosch subsidia-