TO TURN OFF GAS TO APPLIANCE
1. Close main manual gas valve and slide the gas valve

button to the OFF position.

PRESSURE REGULATION

The  pressure  regulator  supplied  with  the  water  heater  is
adjusted to operate on the gas specified on the rating plate
and:
-

in  Canada,  is  factory  preset  to  deliver  gas  at  the  high
altitude pressure setting listed on the rating plate and as
shown below.

-

in the U.S., is factory preset to deliver gas at the standard
altitude setting listed on the rating plate and as shown
below.

The pressure setting of the gas pressure regulator should
be checked at installation to assure that the setting is correct
for  the  gas  being  used  and  the  altitude  at  which  the
appliance  is  installed.  See  rating  plate  on  the  unit,  or  the
chart below for proper settings.
In Canada for a heater being installed at standard altitude
(0- 2.000 ft. elevation) the manifold pressure should be reset
at installation to value shown on the rating plate, or chart
below for standard altitude.
The gas pressures specified below refer to flow pressure
taken at the pressure tap in the gas inlet pipe (just above
pressure regulator, figure 5) while the heater is operating at
full input.

 Note: The  high  altitude  ratings  listed  are  Canadian  Gas

Association high altitude ratings for the appliances and are
only valid in Canada. In the U.S. the National Fuel Gas Code,
ANSI  Z  223.1/NFPA  54,  recommends  for  high  altitude
installations, above 2000 feet that the input rate be reduced
4% for each 1.000 feet above sea level.

WATER TEMPERATURE CONTROL

To adjust water temperature use water flow selector, at
heater. For hot water rotate control Knob to the right.

Turn counter-
clockwise:
more water
- Warm

The  control  knob  regulates  the  water  temperature  by  ad-
justing the flow rate of the water through the heater:
-

Maximum  flow  rate  through  the  heater  is  5L/min,  (1.3

U.S. gal/min.) with temperature rise of 25°C (45°F) at
full input.

-

Minimum flow rate through the heater is 2.3 L/min. (0.6

U.S. gal/min) with temperature rise of 55°C (99°F) at
full input.

For  normal  hot  water  use  the  control  knob  of  water  flow
selector should be turned clock wise 

(        ) 

to stop and

remain  in  that  position.  This  will  permit  control  of  remote
temperature by mixing more or less cold water with the hot
water supplied by the heater.

Note: If  flow  rate  is  adjusted  to  a  point  where  water  flow

through the heater is less than 2.3 L/min. the main
burner will shut-off. This is a safety feature.

Warning:

 Hot water can produce 3

rd

 degree burns,

in 6 seconds at 60°C (140°F)
In 30 seconds at 54°C (130°F)

HIGH TEMPERATURE LIMIT SWITCH

The BOSCH W125K…instantaneous gas water heater is
equipped  with  a  high  temperature  unit  switch  with  a  set
point of 90°C (194°F). If the water temperature at the sensing
bulb  should  exceed  90°C  (194°F)  the  switch  will  open,
interrupting the safety circuit and stopping gas flow to the
pilot and main burner.

Pilot outage as a result of high limit operation indicates that
the heater is not functioning properly. The heater should be
checked  by  a  qualified  serviceman  and  the  reason  for
malfunction  corrected.  To  relight  pilot  follow  instructions
provided on the unit.

Appliance Regulator Pressure Setting

PEEPHOLE

GAS VALVE BUTTON

WATER FLOW
SELECTOR

PILOT IGNITOR BUTTON

Turn
clockwise:
less water
- hot

PRESSURE TAP

PRESSURE REGULATOR

MANUAL  GAS  VALVE

kPa

Inches, W.C.

natural

1.41

5.7

standart

propone

2.61

10.5

(0.2,000 ft.)

natural

1.144

.6

high

propane

2.09

8.4

(2,000-4,500 ft.)

Type of Gas

Pressure tap

Altitude

Содержание W 125 T1

Страница 1: ...TO INSTALLER Please leave this manual with the owner or affix adjacent to appliance Instantaneous gas water heater WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flamma ble vapors and liquids in the vicinity of this or any other applicance WHAT TO DO IF YOU SMELL...

Страница 2: ...nds for high altitude installations above 2 000 feet that the input rate be reduced 4 for each 1 000 feet above sea level DIMENSIONS Figure 1 Standard High Standard High 5 7 4 6 10 5 8 4 3 35 2 7 10 2 8 1 LPG Altitude Tap pressure inch Manifold burner pressure inch Altitude Tap pressure inch Manifold burner pressure inch NG A B C D E F G H J M 270 610 230 190 70 562 350 312 102 138 10 5 8 25 3 8 9...

Страница 3: ...ocated in an area where leakage of the heater or its connections will not result in damage to the area adjacent to the heater or to lower floors of the structure Note When such locations can not be avoided it is recommended that a suitable drain pan adequately drained be installed under the heater The pan must not restrict combustion air flow AIR REQUIREMENTS For safe operation sufficient air for ...

Страница 4: ... Canada CAN 1 B149 Installation Code for detailed requirements In U S ANZI Z223 I NFPA 54 National Fuel Gas Code for detailed requirements The minimum length of a vertical vent up to the terminal must be 2 feet WATER CONNECTIONS The W125K comes supplied with a NPT cold water inlet adapter and a flexible wire braid hot water outlet with a NPT connection Figure 2 RELIEF VALVE The listed pressure rel...

Страница 5: ...k for gas leakage Soap and water solution or other material acceptable for this purpose shall be used in locating gas leaks Matches candles lighters or other ignition sources shall not be used for this purpose WARNING The heater and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess 3 45 KPa psi...

Страница 6: ...ead the safety information first section of the Lighting Instruction Plate on the cover 2 The main manual gas valve must be closed turn valve handle clockwise see fig below and the gas valve button slide to the far left under the OFF mark 3 Wait five 5 minutes to clear out any gas If you smell gas stop Follow B in the safety information above on this label If you don t smell gas go to next step 4 ...

Страница 7: ...e right Turn counter clockwise more water Warm The control knob regulates the water temperature by ad justing the flow rate of the water through the heater Maximum flow rate through the heater is 5L min 1 3 U S gal min with temperature rise of 25 C 45 F at full input Minimum flow rate through the heater is 2 3 L min 0 6 U S gal min with temperature rise of 55 C 99 F at full input For normal hot wa...

Страница 8: ...3 Wash in soap and water and then rinse 4 Reassemble Check for gas leaks after reassembly and correct as required 5 Refer to Lighting Procedure to relight the heater VENTING The vent piping and finned heat exchanger should be checked at least once a year for dust and carbon deposits and cleaned as necessary PRESSURERELIEF VALVE At least once a year the pressure relief valve should be checked to in...

Страница 9: ...OT WATER OUTLET HAS BEEN UPGRADED TO A FLEXIBLE TUBE NOTE POSITIOON OF ASSEMBLY FLAT COPPER WASHER INSIDE BUSHING THEN ATTACHED TO MALE END OF FLEX TUBE DO NOT OVER TIGHTEN 8 703 305 197 8 700 203 027 8 700 703 038 ...

Страница 10: ...10 ...

Страница 11: ...11 Pilot burner 75 8708105538 11a Filter 8700507055 12 Pilot injector 5 NG 8708200005 12 Pilot orifice 49 LPG 8748200173 13 Pilot gas pipe 8700707334 14 Thermocouple 8747202083 15 Gas valve NG 8707011466 15 Gas valve LPG 8707011145 16 Magnetic unit 8707201012 17 Termo connection 8747202209 18 Water valve 8707002497 19 Repair set for water valve cover 8703406204 20 Diaphragm 8700503050 21 Slow igni...

Страница 12: ...ASTRAVAN DISTRIBUTORS LTD 123 Charles Street North Vancouver B C V7H 1S1 Phone Canada 604 929 5488 Phone USA 206 860 8448 Web Site www astravan com ...

Страница 13: ...e eau instantané à gaz AVERTISSEMENT Si les instructions de ce manuel ne sont pas scrupuleusement observées il pourra exister un risque d incendie ou d explosion susceptible de provoquer des dommages matériels et ou des blessures graves ou mortelles Ne pas remiser ou utiliser de l essence ou un autre produit inflammable liquide ou gazeux au voisinage de cet appareil ou de tout autre appareil ménag...

Страница 14: ... thermique de 4 pour chaque palier de 1000 pieds au delà de 2000 pieds au dessus du niveau de la mer DIMENSIONS Figure 1 RACCORDEMENT GAZ RACCORDEMENT EAU SORTIE D EAU OBSTRUÉE A B C D E F G H J M 270 610 230 190 70 562 350 312 102 138 10 5 8 25 3 8 9 1 8 7 1 2 2 3 4 22 1 8 13 3 4 12 1 4 4 5 3 8 Standard Haute Standard Haute Pression de connexion po 5 7 4 6 Pression de connexion po 10 5 8 4 Pressi...

Страница 15: ...ne éventuelle fuite d eau ne fera pas subir de dommages aux locaux adjacents ou des étages inférieurs du bâtiment Note Si l emplacement d installation ne peut satisfaire ces critères on recommande d installer sur le chauffe eau un plateau de récupération adéquatement relié à une canalisation d évacuation Le plateau utilisé ne doit pas entraver la circulation d air de combustion DEMANDE D AIR Une q...

Страница 16: ...uation doit être raccordée à un conduit d évacuation sans obstruction de même taille ou plus grand voir la plus récente édition des normes suivantes Norme CAN1 CGA B149 Code d installation des appareils à combustion de gaz pour le Canada Norme ANSI Z223 1 National Fuel Gas Code pour les É U La longueur minimale d un conduit d évacuation vertical jusqu au point de décharge est de 2 5 pi RACCORDEMEN...

Страница 17: ...tification des fuites utiliser une solution de savon et eau ou un autre produit acceptable à cette fin Ne jamais utiliser allumette bougie briquet ou autre source de flamme pour rechercher les fuites AVERTISSEMENT À l occasion de tout test de pressurisation de la tuyauterie de gaz à une pression supérieure à 3 45 kPa 1 2 lb po rel on doit déconnecter le chauffe eau et son robinet d arrêt individue...

Страница 18: ...Le robinet d arrêt manuel principal de la canalisation de gaz doit être fermé rotation du bouton dans le sens horaire voir la figure ci dessous pousser également le bouton du robinet de gaz au maximum vers la gauche sous la marque ARRÊT 3 Attendre cinq 5 minutes l évacuation de tout résidu de gaz Si une odeur de gaz est perceptible arrêter Observer les instructions de sécurité B présentées ci dess...

Страница 19: ...sélection fait varier la température de l eau par contrôle du débit d eau à travers le chauffe eau Le débit maximum de circulation de l eau à travers le chauffe eau est de 5 L min ceci correspond à une augmentation de température de 25 C 45 F pour le débit thermique maximum Le débit minimum de circulation de l eau à travers le chauffe eau est de 2 3 L min ceci correspond à une augmentation de temp...

Страница 20: ...fuites après le remontage veiller à éliminer toute fuite 5 Pour allumer de nouveau le chauffe eau voir la section Allumage ÉVACUATION DES GAZ DE COMBUSTION Inspecter l échangeur de chaleur et la canalisation d évacuation à intervalles de douze mois ou moins rechercher les dépôts de poussière et carbone effectuer tout nettoyage nécessaire SOUPAPE DE SÉCURITÉ À intervalle de un an ou moins inspecter...

Страница 21: ...E EST UTILISÉ POUR LA SORTIE D EAU CHAUDE NOTER LA CONFIGURATION D ASSEMBLAGE RONDELLE PLATE DE CUIVRE À L INTÉRIEUR DU RACCORD INSTALLÉ À L EXTRÉMITÉ MÂLE DU CONDUIT FLEXIBLE NE PAS SERRER EXCESSIVEMENT 8 703 305 197 8 700 203 027 8 700 703 038 ...

Страница 22: ...10 ...

Страница 23: ...ge 8708107002 11 Veilleuse 8708105538 11a Filtre 8700507055 12 Injecteur de veilleuse 5 GN 8708200005 12 Injecteur de veilleuse 49 PROP 8748200173 13 Tube veilleuse 8710707166 14 Thermoélément Sécurité veilleuse 8747202083 15 Bloc gaz GN 8707011466 15 Bloc gaz PROP 8707011145 16 Tête magnétique 8707201012 17 Thermocâbles 8747202209 18 Valve eau 8707002497 19 Couvercle d étanchétité 8703406204 20 M...

Страница 24: ...ASTRAVAN DISTRIBUTORS LTD 123 Charles Street North Vancouver C B V7H 1S1 Téléphone Canada 604 929 5488 Téléphone É U 206 860 8448 Site Internet www astravan com ...

Отзывы: