OPERATING  INSTRUCTIONS

WARNING

If the water heater has been damaged or exposed to flood-
ing, fire, or sooting do not operate the heater until all cor-
rective steps have been taken by a qualified serviceman.

FILLING

Before proceeding with operation of the water heater make
sure that the system is filled with water.
-

Turn the water flow selector handle clockwise 

(          )

against stop.

-

Open all hot water faucets connected to the W125K…to
allow trapped air to escape from heater and piping.

-

Close  all  faucets,  once  water  flows  freely  and  all  air
has escaped from system.

-

The water heater is now ready to be lit.

SERVICE HINT

The screen (strainer) in the water valve, located in inlet of
the  water  valve,  may  require  occasional  cleaning  due  the
foreign  material  in  the  water  supply.  This  will  restrict  the
flow of water and may affect heater operation and prolong
filling time. To inspect the screen, close the cold water sup-
ply valve ahead of the heater, disconnected  cold water line
from inlet of water valve and remove screen from inlet. Clean
if  required,  replace  screen  in  inlet  to  water  valve,  recon-
nected and open cold water supply valve.

LIGHTING

Light the water heater in accordance with the instructions
on  the  Lighting  and  Operating  Plate  on  the  water  heater.
For your convenience, the instructions are repeated below.

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information, (first section) of the

Lighting Instruction Plate on the cover.

2. The main manual gas valve must be closed (turn valve

handle  clockwise

   

  ,  see  fig.  below  )  and  the  gas

valve button    slide to the far left under the OFF
mark.

3. Wait five (5) minutes to clear out any gas. If you smell

gas, stop! Follow ‘’B’’ in the safety information above on
this label. If you don’t smell gas, go to next step.

4. The pilot burner is located behind the peephole located

in  the  front  center  of  the  jacket  directly  below  this
instruction plate.

5. Slide the gas valve button to right to pilot position (

      

)

and open main manual gas valve (by turning valve handle
counterclockwise  

          

).

6. Fully depress gas valve button (

     

) and light pilot by

pushing pilot igniter button (

       

)

7. Observe  pilot  flame  through  peephole.  The  gas  valve

button  should  be  held  down  at  least  10  seconds  with
pilot burning. When the gas valve button is released the
pilot should continue to born.

-

If the gas valve button does not pop up when released
stop and immediately call your service technician or gas
supplier.

-

If the pilot will not stay lit after several tries, slide the gas
valve button to the left. Under the OFF (     ) mark, turn
the  manual  gas  valve  to  the  off  position  and  call  your
service technician or gas supplier.

8. Slide  gas  valve  button  to  the  right  to  the  ON  position

(

           

) the heater will now fire when water is drawn at

a rate greater than the threshold flow rate (see manual).

Note: If main burner should fait to ignite make sure pilot is
burning. If not repeat lighting procedure steps 1 through 8.

Содержание W 125 T1

Страница 1: ...TO INSTALLER Please leave this manual with the owner or affix adjacent to appliance Instantaneous gas water heater WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flamma ble vapors and liquids in the vicinity of this or any other applicance WHAT TO DO IF YOU SMELL...

Страница 2: ...nds for high altitude installations above 2 000 feet that the input rate be reduced 4 for each 1 000 feet above sea level DIMENSIONS Figure 1 Standard High Standard High 5 7 4 6 10 5 8 4 3 35 2 7 10 2 8 1 LPG Altitude Tap pressure inch Manifold burner pressure inch Altitude Tap pressure inch Manifold burner pressure inch NG A B C D E F G H J M 270 610 230 190 70 562 350 312 102 138 10 5 8 25 3 8 9...

Страница 3: ...ocated in an area where leakage of the heater or its connections will not result in damage to the area adjacent to the heater or to lower floors of the structure Note When such locations can not be avoided it is recommended that a suitable drain pan adequately drained be installed under the heater The pan must not restrict combustion air flow AIR REQUIREMENTS For safe operation sufficient air for ...

Страница 4: ... Canada CAN 1 B149 Installation Code for detailed requirements In U S ANZI Z223 I NFPA 54 National Fuel Gas Code for detailed requirements The minimum length of a vertical vent up to the terminal must be 2 feet WATER CONNECTIONS The W125K comes supplied with a NPT cold water inlet adapter and a flexible wire braid hot water outlet with a NPT connection Figure 2 RELIEF VALVE The listed pressure rel...

Страница 5: ...k for gas leakage Soap and water solution or other material acceptable for this purpose shall be used in locating gas leaks Matches candles lighters or other ignition sources shall not be used for this purpose WARNING The heater and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess 3 45 KPa psi...

Страница 6: ...ead the safety information first section of the Lighting Instruction Plate on the cover 2 The main manual gas valve must be closed turn valve handle clockwise see fig below and the gas valve button slide to the far left under the OFF mark 3 Wait five 5 minutes to clear out any gas If you smell gas stop Follow B in the safety information above on this label If you don t smell gas go to next step 4 ...

Страница 7: ...e right Turn counter clockwise more water Warm The control knob regulates the water temperature by ad justing the flow rate of the water through the heater Maximum flow rate through the heater is 5L min 1 3 U S gal min with temperature rise of 25 C 45 F at full input Minimum flow rate through the heater is 2 3 L min 0 6 U S gal min with temperature rise of 55 C 99 F at full input For normal hot wa...

Страница 8: ...3 Wash in soap and water and then rinse 4 Reassemble Check for gas leaks after reassembly and correct as required 5 Refer to Lighting Procedure to relight the heater VENTING The vent piping and finned heat exchanger should be checked at least once a year for dust and carbon deposits and cleaned as necessary PRESSURERELIEF VALVE At least once a year the pressure relief valve should be checked to in...

Страница 9: ...OT WATER OUTLET HAS BEEN UPGRADED TO A FLEXIBLE TUBE NOTE POSITIOON OF ASSEMBLY FLAT COPPER WASHER INSIDE BUSHING THEN ATTACHED TO MALE END OF FLEX TUBE DO NOT OVER TIGHTEN 8 703 305 197 8 700 203 027 8 700 703 038 ...

Страница 10: ...10 ...

Страница 11: ...11 Pilot burner 75 8708105538 11a Filter 8700507055 12 Pilot injector 5 NG 8708200005 12 Pilot orifice 49 LPG 8748200173 13 Pilot gas pipe 8700707334 14 Thermocouple 8747202083 15 Gas valve NG 8707011466 15 Gas valve LPG 8707011145 16 Magnetic unit 8707201012 17 Termo connection 8747202209 18 Water valve 8707002497 19 Repair set for water valve cover 8703406204 20 Diaphragm 8700503050 21 Slow igni...

Страница 12: ...ASTRAVAN DISTRIBUTORS LTD 123 Charles Street North Vancouver B C V7H 1S1 Phone Canada 604 929 5488 Phone USA 206 860 8448 Web Site www astravan com ...

Страница 13: ...e eau instantané à gaz AVERTISSEMENT Si les instructions de ce manuel ne sont pas scrupuleusement observées il pourra exister un risque d incendie ou d explosion susceptible de provoquer des dommages matériels et ou des blessures graves ou mortelles Ne pas remiser ou utiliser de l essence ou un autre produit inflammable liquide ou gazeux au voisinage de cet appareil ou de tout autre appareil ménag...

Страница 14: ... thermique de 4 pour chaque palier de 1000 pieds au delà de 2000 pieds au dessus du niveau de la mer DIMENSIONS Figure 1 RACCORDEMENT GAZ RACCORDEMENT EAU SORTIE D EAU OBSTRUÉE A B C D E F G H J M 270 610 230 190 70 562 350 312 102 138 10 5 8 25 3 8 9 1 8 7 1 2 2 3 4 22 1 8 13 3 4 12 1 4 4 5 3 8 Standard Haute Standard Haute Pression de connexion po 5 7 4 6 Pression de connexion po 10 5 8 4 Pressi...

Страница 15: ...ne éventuelle fuite d eau ne fera pas subir de dommages aux locaux adjacents ou des étages inférieurs du bâtiment Note Si l emplacement d installation ne peut satisfaire ces critères on recommande d installer sur le chauffe eau un plateau de récupération adéquatement relié à une canalisation d évacuation Le plateau utilisé ne doit pas entraver la circulation d air de combustion DEMANDE D AIR Une q...

Страница 16: ...uation doit être raccordée à un conduit d évacuation sans obstruction de même taille ou plus grand voir la plus récente édition des normes suivantes Norme CAN1 CGA B149 Code d installation des appareils à combustion de gaz pour le Canada Norme ANSI Z223 1 National Fuel Gas Code pour les É U La longueur minimale d un conduit d évacuation vertical jusqu au point de décharge est de 2 5 pi RACCORDEMEN...

Страница 17: ...tification des fuites utiliser une solution de savon et eau ou un autre produit acceptable à cette fin Ne jamais utiliser allumette bougie briquet ou autre source de flamme pour rechercher les fuites AVERTISSEMENT À l occasion de tout test de pressurisation de la tuyauterie de gaz à une pression supérieure à 3 45 kPa 1 2 lb po rel on doit déconnecter le chauffe eau et son robinet d arrêt individue...

Страница 18: ...Le robinet d arrêt manuel principal de la canalisation de gaz doit être fermé rotation du bouton dans le sens horaire voir la figure ci dessous pousser également le bouton du robinet de gaz au maximum vers la gauche sous la marque ARRÊT 3 Attendre cinq 5 minutes l évacuation de tout résidu de gaz Si une odeur de gaz est perceptible arrêter Observer les instructions de sécurité B présentées ci dess...

Страница 19: ...sélection fait varier la température de l eau par contrôle du débit d eau à travers le chauffe eau Le débit maximum de circulation de l eau à travers le chauffe eau est de 5 L min ceci correspond à une augmentation de température de 25 C 45 F pour le débit thermique maximum Le débit minimum de circulation de l eau à travers le chauffe eau est de 2 3 L min ceci correspond à une augmentation de temp...

Страница 20: ...fuites après le remontage veiller à éliminer toute fuite 5 Pour allumer de nouveau le chauffe eau voir la section Allumage ÉVACUATION DES GAZ DE COMBUSTION Inspecter l échangeur de chaleur et la canalisation d évacuation à intervalles de douze mois ou moins rechercher les dépôts de poussière et carbone effectuer tout nettoyage nécessaire SOUPAPE DE SÉCURITÉ À intervalle de un an ou moins inspecter...

Страница 21: ...E EST UTILISÉ POUR LA SORTIE D EAU CHAUDE NOTER LA CONFIGURATION D ASSEMBLAGE RONDELLE PLATE DE CUIVRE À L INTÉRIEUR DU RACCORD INSTALLÉ À L EXTRÉMITÉ MÂLE DU CONDUIT FLEXIBLE NE PAS SERRER EXCESSIVEMENT 8 703 305 197 8 700 203 027 8 700 703 038 ...

Страница 22: ...10 ...

Страница 23: ...ge 8708107002 11 Veilleuse 8708105538 11a Filtre 8700507055 12 Injecteur de veilleuse 5 GN 8708200005 12 Injecteur de veilleuse 49 PROP 8748200173 13 Tube veilleuse 8710707166 14 Thermoélément Sécurité veilleuse 8747202083 15 Bloc gaz GN 8707011466 15 Bloc gaz PROP 8707011145 16 Tête magnétique 8707201012 17 Thermocâbles 8747202209 18 Valve eau 8707002497 19 Couvercle d étanchétité 8703406204 20 M...

Страница 24: ...ASTRAVAN DISTRIBUTORS LTD 123 Charles Street North Vancouver C B V7H 1S1 Téléphone Canada 604 929 5488 Téléphone É U 206 860 8448 Site Internet www astravan com ...

Отзывы: