Maximum hydrostatic water pressure - 0.97 MPa (150 p.s.i.)
Maximum recommended working pressure - 0.69 MPa (100 p.s.i.)
Minimum working pressure - 0.01 1 MPa (2 p.s.i.) at 1.6 Litres/min. (0.5 U.S. Gal/min.) free discharge
Minimum recommended inlet water pressure for use with showers 40 p.s.i.g.
Dimensions in millimetres (inches)
* The high altitude ratings listed are Canadian Gas Association high altitude ratings and are only valid in Canada.
In the U.S., the National Fuel Gas Code, ANSI Z223.1/NFPA 54 recommends for high altitude installations above
2,000 feet, that the input rate be reduced 4% for each 1,000 feet above sea level.
DIMENSIONS
Figure 1
Standard
High
Standard
High
5,7
4,6
10,5
8,4
3,35
2,7
10,2
8,1
LPG
Altitude
Tap pressure inch
Manifold burner pressure inch
Altitude
Tap pressure inch
Manifold burner pressure inch
NG
A
B
C
D
E
F
G
H
J
M
270
610
230
190
70
562
350
312
102
138
(10 5/8)
(25 3/8)
(9 1/8)
(7 1/2)
(2 3/4)
(22 1/8)
(13 3/4)
(12 1/4)
(4)
(5 3/8)
Size, mm
Qt.
natural
standart
11.7 kW
1.25 diam.
6
propane
(0-2,000 ft.)
(40,000 Btu/hr)
0.76 diam.
6
natural
high *
10.5 kW
1.25 diam.
6
propane
(2,000-4,500 ft.)
(36,000 Btu/hr)
0.76 diam.
6
Main Burner Orifices
W 125 K…
W 125 K…
Model
Type of Gas
Altitude
Input