VIP X1
| Installation and Operating Manual
EN | 69
Bosch Security Systems | 2006-12 | V2.5
Configuration using a Web browser
Alarm sources
You can configure the possible alarm triggers for the VIP X1 (for example, the
alarm inputs).
Alarm input 1:
to
Alarm input 4:
Select the option
On
to activate the alarm by the corresponding external alarm
sensor. Otherwise, select
Off
.
Select
Active high
if the alarm is to be triggered by closing the contact.
Select
Active low
if the alarm is to be triggered by opening the contact.
Name:
You can enter a name for each alarm input, which is then displayed below the
icon for the alarm input on the
LIVEPAGE
if configured correctly (see
Livepage
configuration
, page 94).
Video loss alarm:
Activate the checkbox if you want an interruption of the video signal to also trig-
ger an alarm.