VIP X1
| Installation and Operating Manual
EN | 81
Bosch Security Systems | 2006-12 | V2.5
Configuration using a Web browser
Relay
You can configure the switching behavior of the relay output. You can specify an
open switch relay (normally closed contact) or a closed switch relay (normally
open contact).
You can also specify whether the output should operate as a bistable or
monostable relay. In bistable mode, the triggered state of the relay is main-
tained. In monostable mode, you can set the time after which the relay will return
to the idle state.
You can select different events that automatically activate the output. It is possi-
ble, for example, to turn on a floodlight by triggering a motion alarm and then
turning the light off again when the alarm has stopped.
Idle state:
Select
Open
if you want the relay to operate as an NO contact, or select
Closed
if the relay is to operate as an NC contact.
Operating mode:
Select an operating mode for the relay.
For example, if you want an alarm-activated lamp to stay on after the alarm
ends, select
Bistable
. If you wish an alarm-activated siren to sound for 10 sec-
onds, for example, select
10 sec
.
Содержание VIP X1
Страница 1: ...VIP X1 ...
Страница 6: ...EN 6 Installation and Operating Manual VIP X1 Contents Bosch Security Systems 2006 12 V2 5 ...
Страница 18: ...EN 18 Installation and Operating Manual VIP X1 Product description Bosch Security Systems 2006 12 V2 5 ...
Страница 102: ...EN 102 Installation and Operating Manual VIP X1 Configuration using a Web browser Bosch Security Systems 2006 12 V2 5 ...
Страница 142: ...EN 142 Installation and Operating Manual VIP X1 Index Bosch Security Systems 2006 12 V2 5 ...
Страница 143: ......