Specifications
Device
Operating voltage
12 ... 24 V DC, power supply unit with various pri-
mary adapters included
PoE: IEEE 802.11af, class 2
Power consumption
Approx. 6 VA
LAN interface
1 × Ethernet 10/100 Base-T,
automatic adjustment,
half/full duplex, RJ45
Data interfaces
1 × RS232/RS422/RS485, bidirectional, ST500
1 × USB 2.0
Alarm inputs
4 × push-in terminals (non-isolated closing con-
tact), maximum trip resistance 10 Ohm
Relay output
1 × push-in terminal, 30 V
p-p
, 2 A
Video input
1 × BNC jacks
0.7 ... 1.2 V
p-p
, 75 Ohm, PAL/NTSC
Audio input (Line In)
1 × 3.5 mm stereo jack socket,
5.5 V
p-p
max., impedance 9 kOhm typ.
Audio output (Line Out)
1 × 3.5 mm stereo jack socket,
3 V
p-p
max., impedance 16 Ohm min.
Microphone input
1 × push-in terminal, 2.8 V
p-p
max. at –20 dB,
impedance 2 kOhm typ., supply 2.3 V typ.
Speaker output
1 × push-in terminal, 6 V
p-p
max., 1 W rms,
impedance 4 Ohm min.
Displays
3 × LED (operating voltage, network connection,
data transfer) in rear panel
Operating conditions
Temperature: 0 ... +50°C (+32 ... +122°F)
relative humidity: 20 ... 80%,
non-precipitating
Regulatory approvals
CE: IEC 60950; UL 1950; AS/NZS 3548;
EN 55103-1, -2; EN 55130-4; EN 55022;
EN 55024; EN 61000-3-2; EN 61000-3-3;
FCC 47 CFR Chapter 1 Part 15
Содержание VIP X1
Страница 1: ...VIP X1 ...
Страница 6: ...EN 6 Installation and Operating Manual VIP X1 Contents Bosch Security Systems 2006 12 V2 5 ...
Страница 18: ...EN 18 Installation and Operating Manual VIP X1 Product description Bosch Security Systems 2006 12 V2 5 ...
Страница 102: ...EN 102 Installation and Operating Manual VIP X1 Configuration using a Web browser Bosch Security Systems 2006 12 V2 5 ...
Страница 142: ...EN 142 Installation and Operating Manual VIP X1 Index Bosch Security Systems 2006 12 V2 5 ...
Страница 143: ......