en | On-Screen Display Menu Navigation
AutoDome Modular Camera System
F01U073308 | 3.0 | 2007.09
VG4-200, VG4-300, VG4-500i Series User’s Manual
Bosch Security Systems, Inc.
Diagnostic Events
Menu
Description
Sub-menu / Description
Exit
Saves and exits the menu.
Alarm Status
Enters the Alarm Status menu and
displays the real time status of
alarm inputs and outputs.
Alarm Inputs 1 to 7, Alarm
Outputs 1 to 3, and Alarm Relay
BIST
Enters the Perform
Built-in Self
Tests
menu. If confirmed, the BIST
tests start and the results
displayed.
YES to start test. NO to exit the
menu.
Typical results displayed as
follows:
BIST
Exit...
Data Flash:
PASS
Bilinx:
PASS
FPGA:
PASS
Digital I/O 1:
PASS
Digital I/O2:
PASS
VCA:
PASS
Homing:
PASS
Internal Temp.
Displays the current dome
temperature.
High Temp Events
Displays the number of times the
high temperature threshold is
exceeded.
Highest Temp
Displays the highest temperature
reached.
Low Temp Events
Displays the number of times the
low temperature threshold is
exceeded.
Lowest Temp
Displays the lowest temperature
reached.
Security Access
Displays the number of times the
locked-command menu is
unlocked.
CTFID Access
Displays the number of times the
Configuration Tool is accessed.
Homing Events
Displays the number of times the
AutoDome was rebooted.
Homing Failed
Displays the number of times the
AutoDome failed to home
properly.