AutoDome Modular Camera System
Configuring and Using the IP AutoDome | en
47
Bosch Security Systems, Inc.
VG4-200, VG4-300, VG4-500i Series User’s Manual
F01U073308 | 1.0 | 2007.09
1. This function is also accessible by using the mouse scroll wheel while in the Live video frame.
2. This button is also used as the "Enter" button to select menu items from the
AUX
tab.
To manually pan throughout the image area, move your cursor over any part of the live video.
The image area displays a directional arrow (
ONMPKLJI
), then click and hold the right mouse
key to pan the camera.
Digital I/O (300 and 500i Series Only)
The alarm relay outputs will display next to the camera image on the LivePage window when
the IP AutoDome is configured to Show Relay Outputs under Service Settings on the Settings
window. The relays on the camera allows you to operate a device (for example a light or a
door opener). To operate, click the relay symbol next to the video image, only if alarms are not
active. The symbol is yellow when the relay is activated.
Fig. 8.7
Digital I/O Panel
System and Event Logs
The System Log field contains information about the operating status of the IP AutoDome and
the connection. The Event Log contains information about alarm conditions (see
Figure 8.8
below).
Figure 8.8
System and Event Logs
8.7.4
Entering a Keyboard Control Command
The
Aux Control
tab is used to enter keyboard control commands. These commands are
composed of a command number plus the appropriate function key (
Show Shot
,
Set Shot Aux
On
or
Aux Off
). A valid combination either issues a command to the camera or displays an on-
screen menu.
8
Focus far
2
9
Focus near
2
10
Iris close
2
11
Iris open
2
12
Sets the PTZ speed for controls 1, 2, 3, 4, 5, 6, and 7
13
Moves the camera to pre-set shot numbers 1, 2, 3, 4, 5, and 6
Number
Description