224
Bosch Rexroth AG
| Tightening Technology
3 608 870 A47
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-
9.8.4.3
Open Protocol
Settings
Data
Open Protocol
Use this menu item to define the setting for communication with Rexroth Open Protocol of the Nexo
cordless Wi-Fi nutrunner.
Rexroth Open Protocol must be selected for data connection to the tightening system 350.
Table 9–71:
Open Protocol tab
Element
Description
Active
If the check box is activated, communication with the Rexroth Open Protocol
is activated.
TCP/IP port
Selects the TCP/IP port for data transfer.
Value range: 0 - 65535
Default setting: 4545
Version
Selects the
Rexroth OP R1.0
data protocol.
Keep alive timeout
Selects the time span within which messages are received. If no message is
received within this time, the connection will be disconnected.
Default setting: 15 seconds
Response timeout
Selects the time span within which the message to acknowledge the data
transfer must be sent (default setting: 10 seconds). This information is only
required for reliable mode. This time will be set a max. of 4 times. If an
acknowledgement of data transfer fails to be received within the 4th time
span, the connection will be disconnected.
Drop enable
As of Nexo firmware version 1400: Options for the removal of the release
after loss of connection:
– never
– after connection lost
– after keep alive timeout
Suppress echo from ID codes
If
Open Protocol
is selected under
Select device
in the
ID code
menu and
Suppress echo from ID codes
is enabled, this will result in the following:
– ID codes that are received via Open Protocol (MID 0050 or MID 0150)
are then not transmitted to the respective subscribers of the ID codes via
Open Protocol (MID 0052).
– This means that this option (default setting: disabled) prevents a situation
where new ID codes are constantly generated but the actual tightening
job is never carried out at the tightening position.
Also forward ID codes from non-
selected sources
Also forward ID codes from non-selected sources
affects the
subscription of ID codes to be transferred (MID 0051). If this option is
enabled, new ID codes from an ID code source, e.g. a scanner, are
transferred in the subscription even if this source has not been configured as
an active ID code device in the NEXO-OS operating system.
Asynchronous mode
Activate
Asynchronous mode
to operate specific uncritical functionalities
asynchronously. This allows for a higher communication speed between
tightening system and communication partner.
Note: Asynchronous mode is only executed for MIDs 0050/0150 and 0019.
Whether the commands were then successfully executed cannot be
guaranteed.
MID 0020 - Keep programmed
counters
As of Nexo firmware version 1400: If the option is activated, the presettings
for the OK and NOK counters are kept.
MID 0030 - Request jobs
As of Nexo firmware version 1400: If the option is activated, the jobs list is
issued.
MID 0573 - Autorun job
As of Nexo firmware version 1400: If the option is activated, the selected job
is automatically run without a new command.
Save
Click
Save
to save the edited data.
Discard
Click
Discard
to discard the edited data.
Содержание Rexroth Nexo
Страница 4: ...4 279 Bosch Rexroth AG Tightening Technology ...
Страница 256: ...256 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 ...
Страница 262: ...262 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...
Страница 263: ...3 608 870 A47 Tightening Technology Bosch Rexroth AG 263 279 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...
Страница 264: ...264 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...
Страница 274: ...274 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...
Страница 276: ...276 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...