54 / 72
MS2N
Connection water cooling
Bosch Rexroth AG
R911347581, Edition 05
1.
Position power connector at thread.
2.
Tighten knurled nut securely, in doing so,
retrace cable.
3.
Check the firm seat of the connection by
short pull on the connector.
4.
Secure the cables, that accruing forces
due to cable vibrations onto the connector
are prevented.
🡆
The plug-in connector is ready for use.
7.4.19 Connect the terminal box.
WARNING
Danger to life by high electric voltage!
−
Follow the general installation and safety
regulations when working on power installa-
tions.
−
Before start-up, connect the protective
conductors on all electric components
according to the connection plan.
−
Install the covers and guards provided for
this purpose before switching on. Lock all
openings of the terminal box with dummy
plugs and close the terminal box with the
intended terminal box lid.
−
Never touch electrical connection points of
the components while power is turned on.
Observe when connecting the terminal box:
•
Connect or disconnect clamp connections
only in de-energized, dry and clean state.
•
Connect the motor to ready-made connec-
tion cables.
•
Remove dummy plug X or Y at the cable entry
side.
•
Select and tighten the cable gland according
to the manufacturer´s details about cable
diameters.
•
The connections must be established such
that a permanent safe electrical connection
is ensured.
•
Establish a safe protective conductor con-
nection.
•
After connecting, lock all openings.
7.5
Connection water cooling
Any installation material, like tubes or mounting
clamps are not in the scope of delivery. Choose a
supply hose with correct inner diameter.