12.4
Electrical Connection
12.4.1
Safety Instructions
It is recommended that you use ready-made Rexroth connection cables.
These cables provide a number of advantages, such as UL/CSA authoriza‐
tion, extreme load capability and resistance as well as a design suitable for
EMC.
Danger of life due to electrical power! Han‐
dling within the area of live parts is extremely
dangerous.
DANGER
●
Any work required on the electric system must only be carried by skilled
electricians. It is absolutely necessary to use power tools.
●
Before working
1. Disconnect.
2. Protect the system or plant against restart.
3. Determine de-energization.
4. Ground and short-out.
5. Cover or shield any adjacent live parts.
●
Before starting to work, check with an appropriate measuring device
whether parts of the system are still under residual voltage (e.g. caused
by capacitors, etc.). If yes, wait until these parts have discharged.
12.4.2
Electric Connection MKE037, MKE047, MKE098 Housing Design "E"
The accessory kit SUP-M02-MKE is necessary to connect the motor. The ac‐
cessory kit is enclosed to the motors at delivery.
Content accessory kit SUP-M02-MKE
Num‐
ber
Designation
1
Connector housing X3 (encoder 10 pole)
11
Contact encoder connector
1
Clamp terminal X2 (MotTemp / Br)
2
Terminal end
1
Package insert SUP-M02-MKE
4
Pan head screw M5 x 14 DIN 912 (coated)
1
Plug-in interlock for X3
DOK-MOTOR*-MKE*GEN2***-PR06-EN-P
Rexroth MKE Synchronous Motors for Potentially Explosive Areas acc. to ATEX and UL/CSA
Bosch Rexroth AG
109/135
Installation