9
Operating Conditions and Application Notes
9.1
Permitted Areas of Use for MKE Motors
9.1.1
Motors with Housing Design "E"
Motor
Test number ATEX
Designation / suitable for
Standard
UL File number
MKE037
PTB 09 ATEX 1128 X
II 2G Ex d IIB T4 Gb X or
II 2D Ex tc IIIC T135 °C Dc IP6X X
Zone 1, 2, 21, 22
EN 60079-0:2009
EN 60079-1:2007
EN 60079-31:2009
E163211
MKE047
MKE098
MKE118
PTB 09 ATEX 1127 X
Fig.9-1:
Areas of Use for MKE Motors with Housing Design "E"
(1)
Hazardous area with explosion protected apparatus
(2)
Control cabinet
(3)
Drive controller
(4)
MKE motor
(5)
Connections
(6)
Motor power cables
(7)
Encoder Cables
Fig.9-2:
Hazardous area - standard (EU)
The respective drive devices and connections of the connection cables (pow‐
er and encoder connection) must lay outside of the hazardous area.
DOK-MOTOR*-MKE*GEN2***-PR06-EN-P
Rexroth MKE Synchronous Motors for Potentially Explosive Areas acc. to ATEX and UL/CSA
Bosch Rexroth AG
75/135
Operating Conditions and Application Notes
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01