Pos
LED
Display
Meaning
H3
"RUN"
Green
Green~
Off
Operating Display
Cyclic I/O data exchange (normal operation)
Configuration error (command/actual assignment different)
The bus connection is not activated by the DP master.
Causes:
●
Wrong PROFIBUS DP station address
●
The PROFIBUS DP station address is assigned several times at the bus.
●
The response monitoring time is expired.
●
Error in master parameter set (GSD file); e. g. wrong PNO-ID number,
wrong buffer size (Prm, Cfg, ...)
●
Wrong parameterization in User_Prm_Data[1]
H4
"BF"
Red
Red~
Off
Bus error
The bus connection is searching for the baud rate.
Parameterization error (invalid parameterization data)
The bus connection has recognized and applied the baud rate.
Green
Static display
Green~
Slow flashing of the display (0.8 s On and 0.2 s Off)
Green~~
Fast flashing of the display (0.125 s On and 0.125 s Off)
Fig.8-3:
Status Displays
8.4.2
Status Display System Stop
The "system stop" state is displayed with the two LEDs "H1 (UL)" and "H2
(DIA)". During a system stop the outputs are set to the safe status ('0') and the
bus traffic to the DP master is interrupted. The system stop can only be quit by
a restart of the assembly ('Network on').
H1 ("UL")
H2 "(DIA") Meaning
Measure
Off / green / green~ Off / red
No system stop
-
Green
Red~
Unknown I/O module
Load new firmware ver‐
sion (service case)
Green~~
Off
Misconfiguration
Verify I/O configuration
Off / green
Red~~
Exceptional error firm‐
ware
Service case
Green~~
Red~~
Exceptional error hard‐
ware
Service case
Fig.8-4:
Display of the "System stop" state
System stop "Unknown I/O mod‐
ule"
The system stop "Unknown I/O module" means that the VAM 11.1/VAM 41.1
detected a module that is not supported by the firmware version of the bus
connection. To operate the I/O module the firmware must be updated. If an error
occurs with the current firmware version, the module has a hardware error.
System Stop"Misconfiguration"
The following I/O configurations lead to a system stop caused by a misconfi‐
guration:
●
No I/O modules equipped
●
More than 16 I/O modules equipped
●
More than 64 bytes inputs equipped
DOK-SUPPL*-VAM*11/41**-PR03-EN-P
Rexroth IndraControl VAM 11.1/41.1 Machine Control Panels
Bosch Rexroth AG
65/83
Commissioning
Содержание Rexroth IndraControl VAM 11.1
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 26: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 24 83 ...
Страница 34: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 32 83 ...
Страница 48: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 46 83 ...
Страница 74: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 72 83 ...
Страница 80: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 78 83 ...
Страница 82: ...Bosch Rexroth AG DOK SUPPL VAM 11 41 PR03 EN P Rexroth IndraControl VAM 11 1 41 1 Machine Control Panels 80 83 ...