![Bosch Rexroth Hagglunds CA 10 Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/bosch/rexroth-hagglunds-ca-10/rexroth-hagglunds-ca-10_installation-and-maintenance-manual_43004043.webp)
42/52
Technical data
RE 15354-WA/04.2015, Installation and maintenance manual, Hägglunds CA 10 - CA 40,
Bosch Rexroth Mellansel AB
Table 20: General data (US)
Table 21:
Specific data (US)
Frame size
CAB 10
CAB 20
CAB 30
CAB 40
Type of mounting
Pipe connections
Shaft loading
See
RE 15354 Data sheet 4.8 Permitted external loads
Hydraulic fluids
Pressure
Maximum operating pressure
psi
3 626
3 626
3 626
3 626
Maximum peak pressure
psi
4 641
4 641
4 641
4 641
Charge pressure
psi
15.1.2: Recommended charge pressure
Maximum case pressure
psi
44
44
44
44
Maximum case peak pressure
3)
psi
116
116
116
116
Temperature limits of case drain oil
Seal type: NBR
Minimum
°F
-22
-22
-22
-22
Maximum
°F
+158
+158
+158
+158
Oil volume in motor case
US gal
0.19
0.26
0.29
0.32
Moment of inertia for rotary group
lb
m
·
ft
2
1.793
2.395
4.978
6.528
Weight
lb
102
139
177
209
3)
Momentary pressure spikes t< 0.1 s of up to 116 psi are permitted
Frame
size
Nominal size
Specific torque
Displacement
Maximum torque
Maximum speed
Maximum
operating power
2)
lb
f
·ft/1000 psi
in
3
/rev
lb
f
·ft
rpm
hp
CAB 10
0008
407
30.7
1 435
350
93
0010
509
38.3
1 792
350
115
0012
636
47.9
2 242
350
141
CAB 20
0016
814
61.3
2 869
350
186
0018
915
69.0
3 227
350
208
0020
1 017
76.7
3 585
350
230
0022
1 144
86.3
4 034
350
255
0025
1 271
95.9
4 481
350
280
CAB 30
0028
1 424
107.3
5 019
350
303
0030
1 526
115.0
5 377
330
304
0032
1 653
124.6
5 827
290
290
0035
1 780
134.2
6 273
290
312
0037
1 907
143.8
6 723
260
300
CAB 40
0040
2 034
153.4
7 169
280
344
2)
Flushing of motor case is required. See