![Bosch Rexroth Hagglunds CA 10 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/bosch/rexroth-hagglunds-ca-10/rexroth-hagglunds-ca-10_installation-and-maintenance-manual_43004030.webp)
Installation
29/52
Bosch Rexroth Mellansel AB
, Installation and maintenance manual, Hägglunds CA 10 - CA 40, RE 15354-WA/04.2015
Fig. 15: Connection side of the motor
7.3.5 Hydraulic ports
When using (thick wall) piping and in frequent reversal drives, it is recommended
to fit flexible hoses between the motor and piping to avoid damage due to vibration
and to simplify installation of the motor. The length of the hoses should be kept fairly
short.
Table 13: Ports
Connection
Description
Dimension
Remarks
A1
Main connection
G 1“
Normally plugged at delivery.
If A is used as the inlet, the motor
shaft rotates counter clockwise,
viewed from the motor shaft side.
C1
Main connection
G 1“
Normally plugged at delivery.
If C is used as the inlet, the motor
shaft rotates clockwise, viewed from
the motor shaft side.
A2
Alternative main
connection
G 1“
Normally plugged at delivery.
C2
Alternative main
connection
G 1“
Normally plugged at delivery.
D1
Drain connection
G 1/2“
Normally plugged at delivery.
D2
Alternative drain
connection
G 1/2“
Normally plugged at delivery.
DD00068761