28/52 Installation
RE 15354-WA/04.2015, Installation and maintenance manual, Hägglunds CA 10 - CA 40,
Bosch Rexroth Mellansel AB
Example 1: Continuously running motor
CAB 20 20
p
h
= 150 bar
V
i
= 1257 cm
3
/rev
n
= 160 rpm.
The motor power is calculated:
E >E
FL
, the motor should be flushed see Table 12: Motor case flushing flow for CAB
20 20
Example2: Intermittently running motor
CAB 20 20, working at two different conditions,
1)
p
h
= 150 bar
n
= 160 rpm
t = 5 s
The motor power is calculated:
2)
p
h
= 0 bar
n
= 0 rpm
t = 25 s
The motor power is calculated:
The average motor power is calculated:
E <E
FL
, no need for flushing.
Fig. 14:
Circuit design for flushing of motor case
DD00069827