![Bosch Rexroth Hagglunds CA 10 Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/bosch/rexroth-hagglunds-ca-10/rexroth-hagglunds-ca-10_installation-and-maintenance-manual_43004041.webp)
40/52
Troubleshooting
RE 15354-WA/04.2015, Installation and maintenance manual, Hägglunds CA 10 - CA 40,
Bosch Rexroth Mellansel AB
Table 17: Troubleshooting hydraulic motor
Fault
Probable cause
Action
The motor does not run.
Mechanical stop in the drive.
Check system pressure. If the pressure has
risen to the relief valve setting, remove the load
from the drive.
The motor does not deliver enough torque
because the pressure difference across the
motor is not enough for the load.
Investigate the pressure level in the system and
correct the setting of the pressure limiting valve
if necessary.
Insufficient or no oil being supplied to motor.
Check the hydraulic system. Check the external
leakage of the motor (D connection).
Motor rotates in wrong direction.
Oil supply connections to motor incorrectly
connected.
Connect the oil supply correctly.
Motor runs jerkily.
Pressure or flow fluctuations in the hydraulic
system.
Find the cause in the system or in the driven
unit.
Noise in the motor.
The motor is being operated with too low
charge pressure.
Adjust the charge pressure to the correct level.
See chapter
Internal faults in the motor.
Investigate the drain oil, if necessary. Put
a magnetic plug in the oil flow and check
the material that sticks to the magnet. Steel
particles indicate damage. Note that fine
material from the castings may be deposited
and does not mean internal damage in the
motor.
External oil leakage on the motor.
The radial lip seal is worn.
Replace the radial lip seal.
14 Troubleshooting
Please, contact your nearest Bosch Rexroth representative.