24/52 Installation
RE 15354-WA/04.2015, Installation and maintenance manual, Hägglunds CA 10 - CA 40,
Bosch Rexroth Mellansel AB
7.3.2 lubrication of spline
For flange mounted motors, the spline shall normally not be subject to radial load.
With no radial load, the spline shaft can be oiled before mounting the motor. If the
motor is subject to radial load, the splines shall be filled up with oil.
volume for lubrication of spline connection
1. Lubricate and install O-ring at leading edge of motor bore. (O-ring is included in
delivery)
2. Check shaft/splines for burrs and lubricate shaft/splines.
3. Mark spline tooth location on outside of motor bore to assist alignment during
installation.
4. Mount the motor on to the shaft. For screw dimensions and tightening torque,
Table 8: Dimensions installation tolerances CA 10 CA 20 and Table 9: Dimensions
installation tolerances CA 30 CA 40
5.
Bolt the motor to the flange.
6. Fill up hydraulic oil to the G3/8 tread. (see
Fig. 11: Flange mounted motor, shaft
7.
Torque the G3/8 plug. Torque = 30 Nm (22 lbf·ft).
8.
Mount the cover. Torque = 10 Nm (7 lbf·ft).
Table 10: Oil volume for lubrication of spline connection
Motor type
litre
US gallon
CA 10
0.12
0.032
CA 20
0.20
0.053
CA 30
0.48
0.127
CA 40
0.70
0.185
Fig. 11: Flange mounted motor, shaft horizontal
If oil here, it can be used
for the spline. Then take
away the o-ring.
O-ring
74.5 x 3.0 mm
(2.93 x 0.12 in)
Oil to be filled before
tightening G 3/8 plug.
Plug G3/8
DD00063756
Cover