5-6
Instructions for Use
Rexroth Diax 04 HVE/HVR
DOK-DIAX04-HVE+HVR*UL*-IB01-EN-P
X1, Connection for integrated bus connections from neighboring device
X1
hve_X1
Fig. 5-9:
Terminal X1
Type
Number of poles
Type of design
ribbon cable connector
30
pins at device
ribbon cable bushing
30
bushing at ribbon cable
Fig. 5-10:
Design
The control electronics of the neighboring drive controllers is supplied via
connector X1. The connection is made starting from the power supply unit
to the drive controllers, by means of the ribbon cables integrated in the
devices. The maximum length of the ribbon cable is 1 m (when using
extensions)!
Note:
This is an internal connection between power supply unit and
drive controller.
X2, Service interface
The X2 interface is only used for service purposes. Therefore this manual
does not contain any further information on this interface.
X3, Emergency stop circuit
X3.fh7
1
2
3
4
5
6
123456
ZKS
ZKS
OFF
ON
ON
OFF
Fig. 5-11:
Terminal X3
Type
Number of poles
Type of design
screw terminal
1 x 6
bushing at connector
Fig. 5-12:
Design
Cross section
single-core
[mm²]
Cross section
multi-core
[mm²]
Wire size
in AWG
gauge No.:
0,14...1,5
0,25 - 1,5
28...16
Fig. 5-13:
Connection cross section
0,22 Nm
Terminal X1
Design
Terminal X3
Design
Connection cross section
Tightening torque