7.3 Electrical connection
i
The ground cable fitted to the generator clamping device
must be disconnected; otherwise false measurements are
possible.
7.3.1
Shunt-screw drive starting motor
Fig. 18
Fig. 18
Fig. 18
Fig. 18
Fig. 18
: Connecting diagram shunt-screw drive starting motor
Measuring and control cables (thin lines)
Power cables (thick lines)
7.3.2
Screw drive starting motor
Fig. 19
Fig. 19
Fig. 19
Fig. 19
Fig. 19
: Connecting diagram screw drive starting motor
Measuring and control cables (thin lines)
Power cables (thick lines)
i
Starting motors with + to ground are to be connected in the
same basic manner.
7.4 Testing starting motors
Operators must wear ear protectors during
testing.
7.4.1
Load test
Is sufficient as a functional test (without test values) reveals:
- Out-of-round collectors
- Worn-out bushings
- Inter-turn short-circuit in armature or excitation winding
- Armature open-circuit
- Close the protective cover over the ring gear.
- Switch on main switch (36).
Indicator lamp (36) lights up.
- Select the key
6
,
12
or
24
(29) in accordance with the starting
motor (6 V, 12 V or 24 V).
LED lights up.
- Adjust current measuring range with key
300
/
1800
(29).
LED lights up.
Ammeter (45) set to current range 300 A.
LED off.
Ammeter (45) set to current range 1800 A.
- Set test speed with key
6000
/
12000
(30).
LED lights up.
Rotational speed display (44) set to test speed 6000 rpm.
LED off.
Rotational speed display (44) set to test speed 12000 rpm.
- Make battery connection by pressing the key
AKKU MINUS
(29).
LED lights up!
Indicator lamp (28) lights up.
- Press
START
key (29).
LED lights up.
- and press
starting motor test
key (51) simultaneously.
Starting motor is running.
i
Two-handed operation!
The keys
START
and
starting motor test
must be
pressed simultaneously to start the starting motor.
- Actuate brake pedal (13).
- Apply load to starting motor in accordance with characteristic
data.
7
14
28
INT.
EXT.
START
6V
12V
24V
300
AKKU
MINUS
1
2
3
5
1500 3000
4
RPM.
RPM.
10A
A
V
+
_
6V 12V 24V
D+/61
AKKU
MINUS
50
1800
60
120
6000
12000
30
50
+6V
+12V
+24V
-300A
-1800A
50
52
458473/7P
51
7
14
28
INT.
EXT.
START
6V
12V
24V
300
AKKU
MINUS
1
2
3
5
1500 3000
4
RPM.
RPM.
10A
A
V
+
_
6V 12V 24V
D+/61
AKKU
MINUS
50
1800
60
120
6000
12000
30a
31
50
50
52
+6V
+12V
+24V
-300A
-1800A
458473/8P
51