14  IaQ series 

Product limited Warranty

PRodUCT lIMITed WaRRanTY

Models Covered

This limited warranty is provided by FHP 
Manufacturing Company (“FHP”) and covers Bosch 
Humidifier (hereinafter referred to as “Product”). 
This warranty is provided to the original purchaser of 

the Product as long as the Product remains installed 
at its original place of installation.

WaRRanTY CoveRaGe

limited Warranty

FHP warrants that the Product at the time of 
shipment by FHP shall remain free from defects in 
workmanship and materials for the shorter of five 
(5) years from proof of certificate of occupancy date, 
five (5) years from proof of certified start up date or 
six (6) years from date of manufacture, provided it is 
installed and properly maintained by a qualified and 

trained HVAC contractor and the other conditions of 

this warranty are met. If FHP determines that the 

Product or any part of the Product has a defect in 

workmanship or materials, FHP, at its option, will 
repair or replace the defective part.

Humidifier Pad

FHP warrants that the Product shall remain free 

from defects in workmanship and materials for the 
shorter of one (1) year from date of installation or 
eighteen (18) months from date of manufacture, 

provided it is installed and properly maintained by a 
qualified and trained HVAC contractor and the other 
conditions of this warranty are met. If FHP 

determines that the Product has a defect in 

workmanship or materials, FHP, at its option, will 
repair or replace the defective part.

ITeMs noT CoveRed

This limited warranty does not cover the following 
circumstances:
1.   Components or parts not provided by FHP.

2.   Components or parts on which the tags or 

nameplates have been removed, altered or 

defaced.

3.   Scratches in or discoloration of finishes.
4.   Serviceable items and normal maintenance as 

required per the Installation and Maintenance 
Manual.

5.   The workmanship of any installer. FHP disclaims 

and does not assume any liability of any nature 
for unsatisfactory performance caused by 
improper installation, repair or maintenance.

6.   Any labor or material costs for removal, 

reinstallation, repair and replacement of the 

defective component or part.

7.   Electricity or fuel costs, or any increases or 

unrealized savings in same, for any reason 
whatsoever.

8.   Damage caused by excessive temperatures or 

pressures, fuel or gas explosion, electrochemical 
reaction, water and air impurities, electrical 

failures, use during construction, flooding or 
acts of God.

9.   Any damage or failure resulting from the 

introduction of harmful chemicals, caustic fluids, 

or liquids detrimental to any unit component, 
including but not limited to improperly applied 

or maintained heat transfer fluids or chlorinated 

pool or spa water

10.  Any damage or failure resulting from improper 

unit sizing.

11.  Shipping charges, delivery expenses or 

administrative fees incurred by the purchaser in 

repairing or replacing the Product.

CondITIons of WaRRanTY

The warranty herein is void under the following 
circumstances:
1.   Failure or malfunction resulting from improper 

or negligent operation, accident, abuse, 

freezing, electrical imbalance characteristics, 
misuse, unauthorized alteration, incorrect 

electrical supply, electrical surges, or improper 
installation, repair or maintenance. See the 
Installation and Maintenance Manual for 
installation and maintenance information.

Содержание HUMBLBP-17H6--A

Страница 1: ...Installation and Maintenance Manual IAQ Series HUMBSBP 12H6 A HUMBLBP 17H6 A 6 720 220 343 Revised 07 12 FLOW THROUGH BYPASS HUMIDIFIER FOR INSTALLATION ON A VERTICAL PLENUM SURFACE OF ANY air Handler ...

Страница 2: ... Air Wall Base 6 Duct Mounting on the Return Air Duct Base 6 HUM TST H A Calibration Instructions 7 Wiring 7 Checkout 7 Settings 7 Care and Maintenance 7 How the Humidifier Works 8 Humidifier Packaged Component Accessories 8 Contact your local Bosch Dealer or Installing Contractor for product support 8 Heat Pump Wiring Diagram 9 Alternate Electrical Control Connections 10 Parts List for Humidifier...

Страница 3: ...abs on the top and bottom exposing the humidifier evaporator pad Remove the evaporator pad drain pan and distributor trough all of this should come out as one piece Step 2 The BOSCH humidifier may be installed on either the supply or return plenum of a forced air handling system Select a location for the humidifier that allows for service and maintenance Cut out a rectangle Extend horizontal cente...

Страница 4: ...tom and that the spout aligns with the outlet in the cabinet The evaporator pad assembly can only be installed in one direction Ensure that the notch at the top in the distributor trough goes in first Do not force the evaporator pad assembly If it does not go in easily it might be backwards STEP 8 Replace the humidifier cover ensuring that both tabs snap into place Step 9 Turn damper knob to the w...

Страница 5: ...se foam tape to prevent drafts from affecting the humidistat operation See Figure 6 3 Squeeze the top and bottom of the base to release the face of the humidistat 4 Mount the base horizontally over the wires Attach directly to the wall using the two screws provided in the slotted holes HUMIDITY CONTROL Humidistat HUMB TST A A n INSTALLER Leave owner s manual with home owner SAFETY n Improper elect...

Страница 6: ...nting holes 4 Place the outer portion of the mounting gaskets on the plastic base and mount the base with four screws Low voltage wire may enter the humidistat under the gasket 5 Connect wires to terminals on the control assembly as shown in wiring diagrams Replace the face plate DUCT MOUNTING ON THE RETURN AIR DUCT BASE Humidistat dehumidistat versions recommended Caution Do not install the humid...

Страница 7: ...ng s structure can cause loss of structural strength Condensation can also enable mold and mildew growth resulting in personal injury and damage to building structure and contents CARE AND MAINTENANCE Your humidifier is engineered to give helpful and trouble free humidification For maximum efficiency and to ensure the safe and proper operation of your humidifier the following cleaning procedures s...

Страница 8: ... the warm air plenum through the humidifier and returned to the cold air plenum Moisture is evaporated to the air passing through the evaporator pad Minerals are not blown into the air stream as occurs in atomizing humidifiers they are left on the evaporator pad where a high percentage is carried off with the waste water When the humidifier is installed and operating no adjustments are necessary o...

Страница 9: ...6 720 220 343 Revised 07 12 Subject to change without prior notice Primary Heat Pump Wiring Diagram IAQ Series 9 Primary Heat Pump Wiring Diagram ...

Страница 10: ...SNSR 24V SOLENOID VALVE 24 V TRANSFORMER OUTDOOR TEMP SENSOR OUTDOOR TEMP SENSOR COMMON LEAD FURNACE C HI LO CURRENT SENSING RELAY MULTI SPEED BLOWER MOTOR HOT C 115v 60CY ON OFF SWITCH 24V SOLENOID VALVE 24V SOLENOID VALVE 24 V TRANSFORMER L1 C NO HOT L2 115v 60CY ON OFF SWITCH PRESSURE SWITCH 24 V TRANSFORMER HUMIDISTAT HUMIDISTAT WIRE JUMPER WIRE JUMPER 2 3 4 Manual Humidistat 1 To furnace cont...

Страница 11: ...38002913 LBP 17 Pad Rail 7738002926 SBP 12 Pad Rail 7738002914 Distributor Trough 7738002915 Drain Pan 7738002917 LBP 17 Side Panel 7738002924 SBP 12 Side Panel 7738002918 Nozzle 7738002919 LBP 17 Cover 7738002925 SBP 12 Cover 7738002920 Spout 7738002921 Brass Insert Tube P102 Compression Sleeve Brass P101 Compression Nut Table 2 Bosch Humidifier Specifications Expected Humidity Performance Covera...

Страница 12: ...ubject to change without prior notice Revised 07 12 12 IAQ Series Humidifier Dimensional Drawings Humidifier Dimensional Drawings Figure 6 HUMBSBP 12H6 A Dimensional Drawing Figure 7 HUMBLBP 17H6 A Dimensional Drawing ...

Страница 13: ...r to CARE AND MAINTENANCE section of this manual to estimate a humidity setting for the home based on outside temperature No humidifier operation in ON position 1 Set thermostat to operate air handler in heating mode Operation may be necessary for system power 2 Check voltage at humidifier control terminals Voltage should be 20 30 VAC 3 Inspect humidifier wiring Refer to wiring diagrams DO NOT LEA...

Страница 14: ...es not cover the following circumstances 1 Components or parts not provided by FHP 2 Components or parts on which the tags or nameplates have been removed altered or defaced 3 Scratches in or discoloration of finishes 4 Serviceable items and normal maintenance as required per the Installation and Maintenance Manual 5 The workmanship of any installer FHP disclaims and does not assume any liability ...

Страница 15: ... PURPOSE FHP S SOLE OBLIGATION WITH RESPECT TO THE PRODUCT AND PURCHASER S EXCLUSIVE REMEDIES ARE SET FORTH IN THE FOREGOING LIMITED WARRANTY FHP SHALL NOT BE LIABLE FOR ANY INDIRECT PUNITIVE INCIDENTAL SPECIAL CONSEQUENTIAL OR SIMILAR DAMAGES INCLUDING WITHOUT LIMIITATION INJURY OR DAMAGE TO PERSONS OR PROPERTY OR DAMAGES FOR LOSS OF USE LOST PROFITS INCONVENIENCE OR LOSS OF TIME Caution Some sta...

Страница 16: ...601 N W 65th Court Ft Lauderdale FL 33309 Phone 954 776 5471 Fax 954 776 5529 www bosch climate us ...

Отзывы: