background image

Dehumidifier

 

 
 

Demecto 20

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

 
 

 
 

 

 

Summary of Contents for Demecto 20

Page 1: ...Dehumidifier Demecto 20 ...

Page 2: ...mation 3 4 Intended use 5 Operating instructions 5 Technical data 5 Layout 6 Setting up instructions 7 Before starting up 7 Starting up 7 9 Hose drainage 9 Recommendations for drying with the Comedes Demecto 20 10 11 Maintenance 12 Frequently asked questions 13 EN ...

Page 3: ...me please study these operating instructions in detail especially the safety information If you still have any questions about the device after you have read the operating instructions please do not hesitate to contact us E mail address service comedes com If you give us your telephone number we shall call you back free of charge We look forward to all customer feedback and would be delighted to h...

Page 4: ...ers etc into the inside of the device Place the machine on a stable horizontal and dry surface Do not clean the dehumidifier with water Never spray the device with water Do not clean the device with inflammable liquids or cleaning agents Keep children away from the device Never place any objects on the device and don t sit on the device Do not touch the air vents Never cover the air inlet or outle...

Page 5: ...ice is allowed to be used only by persons who are physically and mentally capable of operating it in accordance with these operating instructions or by persons who have been given training on the use of the device by a responsible person Never switch the device on or off with wet hands Never attempt to carry out any repairs or modifications either of an electrical or a mechanical nature on the dev...

Page 6: ...matically The device does not have approval for operation outside the given temperature range To enable the dehumidifier to dehumidify the air to optimum effect it warms the air The room temperature may therefore rise by 1 2 degrees This is perfectly normal and increases the efficiency of the device To operate efficiently in energy terms the device switches off automatically once the set humidity ...

Page 7: ...ENG 6 www comedes com Layout Figure 1 Figure 2 Control Panel Figure 3 ...

Page 8: ... or use a personal protection plug available from your DIY store To save power and to avoid potential danger disconnect the device when it is not operated Before starting up Make sure that the unit is switched off Starting up Check the cable for damage before you insert the power plug The device may only be used if the power cable is in flawless condition Plug in the power cable and switch the uni...

Page 9: ...ly restart Repeatedly pressing the humidity setting button a target humidity of CO 30 35 40 45 50 55 60 65 70 75 80 85 90 and AU could be set The hysteresis of the device is approximately 3 During operation the current humidity is displayed on the display If the actual humidity is below 35 the display will show LO When the humidity is above 95 the display will show HI Memory Function The unit has ...

Page 10: ...you can continue using the Demecto 20 Hose drainage The Comedes Demecto 20 can also be operated with a drainage hose To do so remove the water tank and fix a drainage hose Ø12mm not included Put the hose into the recess on the tank insert the tank again and guide the hose into a drain channel Make sure that the drain is not higher than the connection on the device to ensure that the water can drai...

Page 11: ...y works if the dew point temperature is positive To ensure that this is the case the dehumidifier is equipped with a modern temperature controlled automatic defroster which maintains the vaporizer temperature between approximately 0 C and 5 C For effective dehumidifying the dew point temperature for the Demecto 20 needs to be above 5 C If the dew point temperature is below this level dehumidifying...

Page 12: ...but not above 27 C Additional heating can be provided by an electric heater if necessary Gas radiant heaters are not suitable To generate the air circulation required fans can be used in the room Please note that the insulation layer may also need to be dried depending on the nature of the building defects This will have to be undertaken by a specialist firm Recommended humidity levels for rooms A...

Page 13: ... more often if necessary To do this switch off the device pull the power cable and remove the water tank at the back of the device Now you can pull down the nylon filter Rinse the filter with warm water and allow to dry Then you can fit it back on the device Check the hose used for the drainage regularly for blockages and damage If the hose is blocked or damaged replace it with a new one ...

Page 14: ...e room which generates vapor or steam 3 Is the room too large The device is very loud 1 Is it stood on a firm suitable surface 2 Is the device in contact with the wall of the room 3 If the floor is tiled we recommend that you place a piece of carpet underneath The fuse constantly burns out The RCD earth leakage circuit breaker constantly trips Stop using the device and contact us at service comede...

Page 15: ...www comedes com Version 082018Demecto20 ...

Reviews: