background image

Page 1 of 16 

Drawing   : - TPC473 
Issue 

: - 1 

Date 

: - 09/02/17 

RM40P 

INDUSTRIAL DEHUMIDIFIER 

OWNER’S MANUAL 

Summary of Contents for 10187MP-US

Page 1: ...Page 1 of 16 Drawing TPC473 Issue 1 Date 09 02 17 RM40P INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL ...

Page 2: ...e 2 of 16 Drawing TPC473 Issue 1 Date 09 02 17 RM40 PACKAGE CONTENTS Item Description Quantity 10187MP US Dehumidifier 1 3086144 Quick release hose coupling 1 3944110 PVC Tube 3 8 I D 7 8M TPC473 Manual 1 ...

Page 3: ... phase plus the additional heat generated by the compressor The air is therefore discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered Continuous circulation of air through the dehumidifier gradually reduces the relative humidity within the area The RM40P dehumidifier is a rugged reliable drying unit designed to operate effectively...

Page 4: ...erants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL 10187MP US HEIGHT 24 2 615 mm WIDTH 15 382 mm DEPTH 14 4 365 mm WEIGHT 57lbs 26 kg AIRFLOW 88 3CFM 150 M3 Hr POWER SUPPLY 110V 60Hz 1 ph FINISH Rotational Moulded polyethylene OPERATING RANGE ...

Page 5: ...g the dehumidifier off and on again OPERATING THE HUMIDISTAT The humidistat works in a similar way to a central heating thermostat but instead of measuring temperature it measures the amount of moisture in the air You may select the level of moisture you require known as Relative Humidity and the unit will operate to achieve that level and then switch off As a general guide the higher the setting ...

Page 6: ...coil If the air temperature is above 25 C frost and or droplets of condensed water should cover the entire evaporator coil 6 When the unit is operated in ambient of less than 15 C a defrost cycle should occur approximately every hour The exact time is impossible to predict as the unit is fitted with a temperature sensitive defrost control If after carrying out the above procedures the unit does no...

Page 7: ...ing accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections including mains cable for damage or loose connections 5 In order to check the defrost operation the unit needs to be operated in an ambient temperature of less than 15 C for at least 1 hour When operated In this condition the unit should defrost at least once every...

Page 8: ... the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing further loss of refrigerant gas 3 The refrigerant compressor fitted to the dehumidifier is a durable unit that should give many years of service Compressor failure can result from the machine losing...

Page 9: ... fault 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1 Contact the Factory Service Center 2 Contact the Factory Service Center Unit vibrates excessively 1 Loose compressor 2 Damaged fan 1 Tighten the nuts on the compressor mounts 2 Replace fan Wate...

Page 10: ...12 1 6 Capillary 3014250 1 64ft 7 Solenoid valve 3020836 1 8 Filter dryer 3020937 1 9 Solenoid coil 3030451 1 10 On Off switch 3035914 1 11 Fan Motor 3035773 1 12 Fan Blade 3040181 1 13 Castor 3050205 4 14 Compressor 3022147 1 15 Condensate Pump 3160156 1 17 Humidistat Knob 2018644 1 18 Pump Fault Lens 3032271 1 19 Pump Fault Light 3036636 1 20 Humidistat 3035158 1 21 Mains Cable 2141095 1 22 Fron...

Page 11: ... WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS SECTION FOR YOUR RECORDS CLIP AND RETURN THIS CARD PLEASE NOTE WARRANTY REGISTRATION To ensure that your Ebac Dehumidifier is accorded the full coverage provided by this warranty please complete and mail this ...

Page 12: ...yoto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label Due to the high pressures within the refrigeration circuit under no circumstances must direct ...

Page 13: ...Page 13 of 16 Drawing TPC473 Issue 1 Date 09 02 17 ...

Page 14: ...Page 14 of 16 Drawing TPC473 Issue 1 Date 09 02 17 ...

Page 15: ...Page 15 of 16 Drawing TPC473 Issue 1 Date 09 02 17 ...

Page 16: ...American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www ebacusa com sales ebacusa com German Sales Office Ebac Industrial Products Ltd Gartenfelder Str 29 37 Gebäude 35 D 13599 Berlin Germany Tel 49 3043 557241 Fax 49 3043 557240 www eip ltd de sales eip ltd de Pure n Natural Systems Inc w...

Reviews: