Service menu
13
HPC 410 – 6721832682 (2021/02)
NOTICE
Risk of damaging or destroying the screed!
▶ With multi-circuit systems, this function can only be used in
combination with a heating circuit with mixer.
▶ Set the screed drying according to the instructions of the screed
manufacturer.
▶ In spite of the screed drying function, visit the systems daily and keep
the prescribed record.
Fig. 6
Screed drying process with default settings in the heat-up
phase
Fig. 7
Screed drying process with default settings in the cooling phase
T
0
Supply temperature
t
Time (in days)
Table 16 Settings in the Screed drying menu (Figs. 6 and 7 show the
default setting of the screed drying program)
Menu item
Control range: Function description
Activated
[Yes]: the required settings for the screed drying are
displayed.
[
No
]: the screed drying is not active and the settings are
not displayed (default setting).
Wait time before
start
[
No wait time
]: the screed drying program starts
immediately for the selected heating circuits.
[1 ... 50] days: the screed drying program starts after the
set waiting time. The selected heating circuits are switched
off during the waiting time, the frost protection is active
(
Fig. 6, time before day 0)
Start phase period [No start phase]: no start phase.
[1 ...
3
... 30] days: setting for the time delay between the
beginning of the start phase and the next phase (
Fig. 6,
[1]).
Start phase temp.
[20 ...
25
... 55] °C: flow temperature during the start
phase (
20
30
40
50
60
0
2
4
6
8
10
12
14
t/d
T
0
/°C
2
3
1
4
0010021148-001
20
30
40
50
60
16
18
20
22
8
10
12
14
t/d
T
0
/°C
6
5
4
7
0010021149-001
Heat-up phase
increment
[No heat-up phase]: no heat-up phase takes place.
[
1
... 10] days: setting for the time delay between the
steps (increment) in the heat-up phase (
Fig. 6, [3])
Ht-up phase temp.
diff.
[1 ...
5
... 35] K: temperature differential between the
steps in the heat-up phase (
Fig. 6, [2])
Holding phase
period
[1 ...
7
... 99] days: time delay between the beginning of
the holding phase (duration of the maximum temperature
for screed drying) and the next phase (
Fig. 6, [4])
Holding phase
temp.
[20 ...
55
] °C: flow temperature during the holding phase
(maximum temperature,
Cool-down phase
incr.
[No cool-down phase]: no cooling phase takes place.
[
1
... 10] days: setting for the time delay between the
steps (increment) in the cooling phase (
Cool-down ph.
temp.diff.
[1 ...
5
... 35] K: temperature differential between the
steps in the cooling phase (
Fig. 7, [6]).
End phase period
[No end phase]: no end phase takes place.
[Perm.]: an end time is not defined for the end phase.
[
1
... 30] days: setting for the time delay between the
beginning of the end phase (last temperature step) and the
end of the screed drying program (
End phase temp.
[20 ...
25
... 55] °C: flow temperature during end phase
(
Fig. 7, [7]).
Max. interruption
time
[2 ...
12
... 24] h: maximum duration of a screed drying
interruption (e.g. by stopping the screed drying or power
failure) until a fault display is output.
Screed dry.
System
[Yes]: screed drying is active for all heating circuits of the
system.
Notice
: single heating circuits cannot be selected. DHW
heating is not possible. The display of menus and menu
items with settings for DHW is switched off.
[
No
]: screed drying is not active for all heating circuits.
Notice
: single heating circuits can be selected. DHW
heating is possible. The menus and menu items with
settings for DHW are enabled.
Screed dry. HC 1 ...
Screed dry. HC 4
[Yes] | [
No
]: setting that specifies whether screed drying
in the selected heating circuit is active/not active.
Start
[Yes]: start screed drying now.
[
No
]: screed drying not yet started or terminated.
Interrupt
[Yes] | [
No
]: setting that specifies whether or not the
screed drying is to be provisionally halted. If the maximum
interruption duration has been exceeded, a fault display is
output.
Continue
[Yes] | [
No
]: setting that specifies whether or not screed
drying is to be resumed once it has been halted.
Menu item
Control range: Function description
Содержание HPC 410
Страница 23: ......