46/68 Installation
Bosch Rexroth Mellansel AB
,
Installation and maintenance manual , Hägglunds CB, RE 15302-WA/05.2019
Vertical mounting of motor
DANGER
Vertical mounted motor: Motor/flange falls down!
Risk to life and risk of injury or serious injuries and
risk of damage to equipment!
▶
Make sure that the flange is correctly mounted to
the foundation and can withstand the weight and
forces from the motor.
▶
Make sure the motor is correctly mounted
to the flange.
▶
Do not stand in the danger zone!
▶
The spline area must always be lubricated with
hydraulic oil to prevent wear of spline interface.
Wear of spline increase relative movement between driven shaft and motor,
which can cause the mounting kit, holding the motor axially, to break.
▶
Torque arm mounted motor with spline and mounting kit can be used only for
horizontal mounting and/or motor driven shaft pointing downwards unless extra
safety arrengements is installed to secure the motor from falling.
DD00100075
Fig. 43: Vertical mounting of coupling motor
DD00100627
Note!
Only recommended for coupling motor
Mounting the motor onto the driven shaft using the assembly tool see
: Mounting the
coupling motor to the driven shaft page 43.
Note!
If splines motor is to be used, contact your Bosch Rexroth representative.