Installation 35/68
RE 15302-WA/05.2019, Hägglunds CB, Installation and maintenance manual ,
Bosch Rexroth Mellansel AB
1
2
3
4
Fig. 31: Articulated connection and hydraulic cylinder for DTCB
5
7
Pos Description
Tightening torque
Pcs
1
Articulated connection
1
2
Pins
4
3
Circlips
4
4
Hydraulic cylinder
1
5
Air bleeding G ¼" (opposite
side of connections)
2
6
Attachment brackets
4
7
Screw M24-8.8
665 Nm / 490 lbf ft
8 (Not included in delivery)
DD00100078
1. Mount the articulated connection on the left side of the torque arm (viewed from
the connection side of the motor), use the pins (2) and lock them in place with
circlips (3).
2.
Mount the hydraulic cylinder with the piston rod facing upwards on the right side
of the torque arm (viewed from the connection side of the motor), use the pins
(2) and lock them in place with circlips (3).
3. Attachment brackets (6) for torque arm should be fastened with screws (7)
4.
Check and adjust the distance C for the cylinder according to
Table 10
(Note!
depending on application this distance can be different). Shim between the
torque arm attachment brackets and the foundation or if possible, adjust the
mounting plate of the foundation to reach the required distance.
6