36/68 Installation
Bosch Rexroth Mellansel AB
,
Installation and maintenance manual , Hägglunds CB, RE 15302-WA/05.2019
Connection
Description
Dimensions
Remarks
T4A
Pressure connection
G½˝
To be connected to
A
on
cylinder
T4C
Pressure connection
G½˝
To be connected to
B
on
cylinder
A
Pressure connection
G½˝
B
Pressure connection
G½˝
C
Air ventilation
G½˝
Air filter
Fig. 32: Hydraulic connections DTCB
Hydraulic connection between motor and hydraulic cylinder
This is valid with the hydraulic cylinder on the right hand-side of the the motor.
See
Fig. 32
1. Mount the hoses, The hose mounted to connection T4A has to be mounted to the
hydraulic cylinder connection (A) and the hose from connection T4C has to be
mounted to the cylinder connection (B).
NOTICE
Overload of driven shaft!
Damage of equipment.
▶
Make sure to follow the installation instructions regarding hydraulic connections
Table 13: Hydraulic connections DTCB
Air bleeding
A port
Air bleeding
B port
A
T4C
C
T4A
B
The cylinders should be vented from air during commisioning by using the air
bleeding screws on the cylinder, see
Fig. 31
DD00100397